17
EN
EN
BOC-P
USER MANUAL
6.2 QUICK CALIBRATION BY USERS
(not applicable for the initial calibration of replacement mainboard or sensor)
When starting up self-check 0~9 number, quickly enter the user’s calibration password
9158
.
WEIGHT
( )
UNIT WEIGHT
(
)
QUANTITY
( )
0.0
put
Au-cal
AFTER LOADING THE CALIBRATION WEIGHTS ABOVE THE HALF-RANGE AND STABILIZING FOR 3 SECONDS,
THE AUTOMATIC CALIBRATION COMPLETES AND EXITS.
6.3 TROUBLE SOLVING
The following table shows the possible causes and solutions of common problems and failures. It is for reference only. If you still have any ques-
tions, please contact the authorized dealer.
Symptoms
Possible Reasons
Check Solution For Reference
CAN NOT TURN ON
NO POWER CONNECTION, NO BATTERY
CHECK THAT THE POWER CONNECTION AND
BATTERY VOLTAGE ARE CORRECT
INSTABILITY
[HOP NUMBER]
THE USE ENVIRONMENT IS UNSTABLE
MOVE THE ELECTRONIC COUNTER TO THE
APPROPRIATE ENVIRONMENT
ACCURACY IS POOR
IMPROPER CALIBRATION
CALIBRATE
CAN’T CALIBRATE
UNSTABLE ENVIRONMENT
MOVE THE ELECTRONIC COUNTER TO THE
APPROPRIATE ENVIRONMENT
THE BACKLIGHT DOESN’T WORK
MODE OFF
ENTER THE MENU SETTINGS ACTIVATION
MODE
ALARM IS INVALID
MODE OFF
ENTER THE MENU SETTINGS ACTIVATION
MODE
BATTERY SYMBOL FLICKER
LOW BATTERY
CHARGE AND REPLACE THE BATTERY IN
TIME
BATTERY FAILURE
BATTERY OUT OF SERVICE
CONTACT THE COMPANY AUTHORIZED
DEALER TO
REPLACE THE BATTERY
THE SCALE IS NOT FULL
THE ZERO OF THE SENSOR IS TOO HIGH
AND THE PRESET TARE IS TOO HEAVY
REPLACE THE SENSOR AND REMOVE THE
PRESET TARE
WEIGHT ON THE SCALE
-------
OVERLOAD
REDUCE THE LOAD ON THE SCALE