Technical data
46
Code no. 550038
Rev. no. 16/1018
4.5.
ETL
certified models.
Specific values for models with GAS heating
Consult the description of the burner in Section 1.2.
VERY IMPORTANT
NOTES RELATING TO POWER AND GAS DETAILS
Volumetric consumptions and massic consumption
. Values calculated at 15ºC (59ºF); 1013.25 mbar
(14.7 PSI).
4.5.1. Atmospheric burner. Heating data
ATMOSPHERIC BURNER.
ETL
models
MACHINE MODEL
UNITS
X13061
X13084
X20075
X20100
X20125
Natural
Supply pressure
mbar
17.4
17.4
17.4
17.4
17.4
(in.wc)
(7.0)
(7.0)
(7.0)
(7.0)
(7.0)
Manifold pressure
mbar
12.4
12.4
12.4
12.4
12.4
(in.wc)
(5.0)
(5.0)
(5.0)
(5.0)
(5.0)
Volumetric consumption
m
3
/h
(cu.ft/h)
2.48
(87.6)
3.06
(108.1)
4.48
(158.2)
5.88
(207.7)
7.09
(250.4)
Nominal calorie cons. with
regard to H
i
(Net)
kW
23.4
28.9
42.3
55.6
67
(BTU/h)
(79844)
(98611)
(144334)
(189715)
(228613)
Nominal calorie cons. with
regard to H
s
(Gross)
kW
26
32.1
47
61.7
74.4
(BTU/h)
(88669)
(109510)
(160286)
(210683)
(253881)
Injector diameter
mm
3.7
4.6
5.05
5.9
6.9
Propane
Supply pressure
mbar
27.4
27.4
27.4
27.4
27.4
(in.wc)
(11.0)
(11.0)
(11.0)
(11.0)
(11.0)
Massic consumption
kg/h
1.72
2.29
3.32
4.2
5.15
(lb/h)
(3.78)
(5.06)
(7.32)
(9.25)
(11.35)
Nominal calorie cons. with
regard to H
i
(Net)
kW
22.5
30.1
43.5
55
67.5
(BTU/h)
(76773)
(102705)
(148428)
(187668)
(230320)
Nominal calorie cons. with
regard to H
s
(Gross)
kW
24.4
32.7
47.3
59.8
73.3
(BTU/h)
(83256)
(111634)
(161331)
(203982)
(250110)
Injector diameter
mm