![GIRBAU ED Series Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/girbau/ed-series/ed-series_operating-and-maintenance-instruction-manual_2229198054.webp)
Maintenance
54
Code no. 576074
Rev. nº 03/0418
11.4. Preventative maintenance programme
7DAY
50 h
QUAR
600 h
ANNUAL
2400h
PROCEDURES RESERVED EXCLUSIVELY FOR THE CUSTOMER’S
TECHNICAL SERVICES OR AUTHORISED TECHNICAL SERVICES
x
Check the heating system ignition and combustion (gas heating)
x
Cleaning the lint filter
x
Clean the protective vents of the extraction motor fan
x
Clean the extraction turbine blades and the exhaust ducts
x
Clean the inverter fan or
x
Clean the inside of the machine
x
Cleaning the inverter fan and heatsink (only if considered necessary).
x
Check the static pressure at the fan output.
REQUEST AN ANNUAL SERVICE FROM AUTHORISED TECHNICAL
SERVICES
x
Check all the functions of the dryer (TEST program)
x
Check the heating system
x
Check the power consumption of the drum motor and the extraction motor
x
Check the power consumption of the electric heaters (electric heating)
x
Check and clean the burner (gas heating)
x
Check the rotation detector
x
Check external protections and electrical earthing
x
Check the gas tightness of the gas circuit (gas version)
x
Check the condition of the nuts and bolts
x
Clean the lint from the machine and from the exhaust area.
x
Analysis of the combustion products
THE RESULT MUST COMPLY WITH
THE REQUIREMENTS IN FORCE IN THE COUNTRY WHERE THE DRYER
IS INSTALLED.