10.2.1. List of main alarms
CODE
ALARMS
CODE
ALARMS
2
Assembly error
12
Output temperature probe
3
Inverter communication fault
13
Input thermostat alarm
4
Inverter overcurrent
14
Output thermostat alarm
5
Motor overheating
15
Rotation fault
6
General inverter fault
16
Gas ignition fault
7
Inverter configuration fault
17
Electric heating fault
8
Lint door open
18
Heating fault
9
Overtemperature
19
Vaccuum fault
10
Heating fault
20
Fan fault
11
Input temperature probe
21
Model error
10.2.2. Troubleshooting
2
ASSEMBLY ERROR
Incorrect microprocessor board connections.
Probable cause:
Incorrect connections or manipulation of the microprocessor board.
Procedure:
Disconnect the power supply and contact Authorised Technical Services.
3
INVERTER COMMUNICATION FAULT
Communication fault between the dryer control microprocessor and the drum motor inverter.
Probable cause:
Fault in the electrical supply from the inverter.
Fault in the communication wiring.
Fault in the inverter’s communication circuits or the microprocessor.
Procedure:
Disconnect the machine from the power supply and reconnect it.
If fault persists, disconnect the power supply and contact Authorised Technical Services.