Girard Products GSWH-1M Скачать руководство пользователя страница 3

USA AND CANADA - FOLLOW ALL APPLICABLE STATE AND LOCAL CODES 

IN THE ABSENCE OF LOCAL CODES OR REGULATIONS REFER TO CURRENT 
STANDARDS OF:

• Recreational Vehicles ANSI A119.2/NFPA 501C.
• CSA standard Z240 RV Series, Recreational Vehicle.
• Park Trailers A119.5
• National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149 Installation Codes
• Federal Mobile Home Construction & Safety Standard, Title 24 CFR, part 3280, or
  when this Standard is not applicable, the Standard for Manufactured Home Installations
  (Manufactured Home Sites, Communities and Set-Ups), ANSI A255.1 and/or CAN/  

 

  CSA-Z240 MH Series, Mobile Homes.
• National Electrical Code ANSI/NFPA No. 70 and/or CSA C22.1

3

P a g e

CRITICAL INSTALLATION WARNINGS

• Installation and Service must be performed by a Girard Products LLC
   recommended installer, service agency or gas supplier.
• This product is not designed for Do-it-Yourself Installation.
• Install ONLY in recreation vehicles (RV’s). RV’s are recreation vehicles designed
  as temporary  living quarters for recreation, camping, or travel use having their own power  
  or towed by another vehicle. This water heater is NOT designed for Marine or Space    
  Heating applications
• All combustion air must be supplied from the outside of the RV, and all products of
  combustion must be vented to the outside of the RV.
• DO NOT vent water heater with a venting system serving another appliance or
   to an outside enclosed porch area.
• DO NOT modify water heater in any way. This is dangerous and will void the
  warranty.
• DO NOT alter water heater for a positive grounding system.
• DO NOT HI-POT water heater unless the electronic ignition control (circuit board) has been  
  turned ‘OFF’ (Power switch is in “Off” position)
• DO NOT use battery charger to supply power to water heater even when testing.
• Protect building materials from flue gas exhaust.
• Install the water heater on an exterior wall, with access door opening to the outdoors.
• DO NOT lift the water heater or carry it by holding the blower assembly support bracket/ 
  exhaust tube.
• DO NOT modify the length of the wires protruding past the strain relief from the
  rear of the housing. 

Содержание GSWH-1M

Страница 1: ...ankless Water Heater LP Gas Power Blower Induced Draft Gas Modulation Control Installation and service must be performed by a recommended installer service agency or gas supplier This water heater is...

Страница 2: ...ven Death WARNING FIRE OR EXPLOSION WARNING These instructions must be followed exactly or a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline...

Страница 3: ...es designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle This water heater is NOT designed for Marine or Space Heating applicati...

Страница 4: ...IONS FROM ANY WINDOW OR OPENING INTO THE VEHICLE DO NOT INSTALL THE WATER HEATER OR ANY OTHER APPLIANCE WHERE IT CAN VENT INTO AN AREA COVERED BY AN AWNING CANOPY OR ANY OTHER ENCLOSURE Note The water...

Страница 5: ...build an appropriate frame using 2 X 2 elements Figure 1 The rough opening for the GSWH 1M should be 12 75 X 12 75 with right angle corners The exterior wall opening must be the same dimensions with...

Страница 6: ...2 Use two wrenches to tighten the compression fitting to avoid damaging the unit Use additional caulking if needed to complete a permanent seal of the gas line with the housing 6 P a g e PRODUCT DAMAG...

Страница 7: ...ng or butyl tape to the back of the door flange that will contact the RV sidewall around perimeter of the opening 6 Insert the door flange into the water heater housing and press the flange firmly aga...

Страница 8: ...ntact the mounting frame 5 Slide the water heater in place into the opening and press the door flange against the sidewall 6 Secure water heater housing unit to the vehicle using No 8 flat head screws...

Страница 9: ...nstall the door making sure that 1 The door mounting posts on the door flange are properly aligned with corresponding holes along the door s lower edge If needed carefully re align the posts with plie...

Страница 10: ...Electrical Code ANSI NFPA 70 and or the CSA C22 1 Canadian Electrical Code Figure 6 This completes the installation of the Model GSWH 1M water heater Insert exhaust tube through door opening CONSUMER...

Страница 11: ...low and the Gas Modulation Control GMC setting The Girard Tankless Water Heater heats water while it is being used i e on demand The output temperature of the water depends on the GMC setting the inle...

Страница 12: ...ater 3 Locate and set Gas Modulator Dial GMC to the appropriate setting see fig 5 on page 8 a Normal Weather Set Dial to the middle area b Extreme Cold Weather Set Dial to the extreme right area large...

Страница 13: ...the water heater in potentially freezing conditions the model GSWH 1M has a built in thermostat that will start the burner whenever the temperature of the Heat Exchanger falls below 38 F and will aut...

Страница 14: ...ng the proper operation of the water heater The model GSWH 1M consists of the following main sub systems and components 1 Water Sub System 1 1 Flow Switch 1 2 Heat Exchanger 1 3 Limit Switch Emergency...

Страница 15: ...rranty 4 Open the cover and verify that no debris or extraneous combustible materials are present anywhere especially in the area of the burner and the gas controls remove any item present and wipe cl...

Страница 16: ...ires a manual reset by either resetting the thermostatic demand turning off the water flow or turning off the power for a period of 5 seconds and then opening the HOT Water Faucet Flame failure If the...

Страница 17: ...17 P a g e Figure 10 WIRING DIAGRAM Figure 9 EXPLODED VIEW OF MODEL GSWH 1M AND MAJOR COMPONENTS IDENTIFICATION...

Страница 18: ...Manifold Pressure 10 10 5 WCI Power Input 12VDC 3 amp Water Operating Pressure 125 PSI Max Dimension Width 12 5 Height 12 5 Depth 15 5 Shipping Weight 22 lbs ECO max Temperature 131 F Specifications T...

Страница 19: ...epairs made confirm that the service center is a recommended service center for Girard Products LLC Water Heaters DO NOT PAY THE SERVICE CENTER FOR WARRANTY REPAIRS WITHOUT PRIOR APPROVAL FROM GIRARD...

Страница 20: ...nental United States Alaska Hawaii and Canada Service Your Girard Tankless Water Heater is manufactured to the highest standards and is designed to provide years of trouble free use but in the event y...

Страница 21: ...az propane liquide Tirage induit par soufflerie Commande de modulation de gaz L installation et l entretien doivent tre effectu s par un installateur une agence de service ou un fournisseur de gaz rec...

Страница 22: ...E EN GARDE Le non respect de ces instructions peut entra ner un incendie ou une explosion causant des dommages mat riels des blessures ou des d c s Ne pas entreposer ni utiliser d essence ou d autres...

Страница 23: ...R sont des v hicules con us comme r sidence temporaire pour les vacances le camping ou les voyages ils peuvent tre autopropuls s ou remorqu s par un autre v hicule Ce chauffe eau N est PAS con u pour...

Страница 24: ...EN TRE OU D UNE OUVERTURE DU V HICULE NE PAS INSTALLER LE CHAUFFE EAU OU TOUT AUTRE APPAREIL DANS UN ENDROIT O L VACUATION SE FERAIT DANS UN ESPACE RECOUVERT D UN AUVENT D UN DAIS OU DE TOUTE AUTRE FE...

Страница 25: ...es de 2 po x 2 po 5 cm x 5 cm Figure 1 L ouverture brute du mod le GSWH 1M doit mesurer 12 75 po x 12 75 po 32 4 cm x 32 4 cm avec des angles droits L ouverture du mur ext rieur doit avoir les m mes d...

Страница 26: ...ent le chauffe eau dans l ouverture et raccorder les conduites d eau chaude et froide aux raccords po NPT appropri s Les raccordements peuvent tre faits l aide d adaptateurs crou tournant PEX filetage...

Страница 27: ...re ou du ruban de caoutchouc butyle au dos de la bride de la porte qui sera en contact avec la paroi lat rale du VR autour de l ouverture 6 Ins rer la bride de porte dans le bo tier du chauffe eau et...

Страница 28: ...era en contact avec le cadre de montage 5 Glisser le chauffe eau dans l ouverture et presser fermement la bride de porte contre la paroi lat rale 6 Fixer le bo tier du chauffe eau au v hicule en ins r...

Страница 29: ...urant que 1 les tiges de montage sur la bride de la porte sont correctement align es avec les trous correspondants le long du rebord inf rieur de la porte Au besoin r aligner d licatement les tiges l...

Страница 30: ...re 6 Cela compl te l installation du chauffe eau mod le GSWH 1M Ins rer le tuyau d chappement dans l ouverture de la porte CONSIGNES DE S CURIT POUR LES CONSOMMATEURS Utiliser du gaz propane liquide s...

Страница 31: ...maximum de 36 000 BTU et la temp rature d eau entrante augmentera de 20 70 F selon le d bit d eau chaude et le r glage de la commande de modulation de gaz Le chauffe eau sans r servoir de Girard chauf...

Страница 32: ...une demande d eau chaude 3 Tourner le bouton de modulation de gaz au r glage appropri voir Figure 5 la page 28 a Temp rature normale R glage au milieu b Temp rature tr s froide R glage droite grande...

Страница 33: ...terrupteur marche arr t en position de marche ON chaque fois que des conditions de gel sont probables Cela ne prot gera pas tout le syst me de plomberie du VR Le VR doit tre con u pour une utilisation...

Страница 34: ...g e composants lectriques montrant toutes les interconnexions et les couleurs de fils adopt es 3 Figure 11 Diagramme de circuit illustrant la logique de contr le et la fonction de chaque composant lec...

Страница 35: ...e fois que l utilisateur ouvre un robinet d eau chaude l eau actionne l interrupteur de d bit qui envoie une demande thermostatique au circuit imprim de l allumage Une fois la demande re ue le circuit...

Страница 36: ...le panneau de l utilisateur Si l indicateur DEL est allum ou s il clignote le type de clignotement indiquera le probl me d tect par le panneau de contr le comme suit Allum sans clignoter probl me de c...

Страница 37: ...37 P a g e Figure 10 DIAGRAMME DE C BLAGE Figure 9 VUE CLAT E DU MOD LE GSWH 1M ET IDENTIFICATION DES PRINCIPAUX COMPOSANTS...

Страница 38: ...ion d entr e 12 VCC 3 A Pression d eau de fonctionnement 125 PSI max Temp rature max de l eau 125 F 52 C Dimension Largeur 12 5 po 31 75 cm hauteur 12 5 po 31 5 cm profondeur 15 5 po 39 cm Poids d exp...

Страница 39: ...AYEZ PAS LE CENTRE DE SERVICE POUR DES R PARATIONS SOUS GARANTIE SANS D ABORD OBTENIR L APPROBATION DE GIRARD PRODUCTS LLC DE TELS PAIEMENTS NE SERONT PAS REMBOURS S 5 Les pi ces d fectueuses ou le ch...

Страница 40: ...zone continentale des tats Unis de l Alaska d Hawa et du Canada Service Votre chauffe eau sans r servoir de Girard Products est fabriqu selon les normes les plus lev es et con u pour fonctionner sans...

Отзывы: