Reduce the connected load. 

Device switches to maximum brightness without being operated 

Cause: device is not receiving any DALI telegrams (see section Behaviour in case of mains 
voltage failure). 

Check DALI control unit. 

6.3 Warranty 

The warranty is provided in accordance with statutory requirements via the specialist trade. 
Please submit or send faulty devices postage paid together with an error description to your 
responsible salesperson (specialist trade/installation company/electrical specialist trade). They 
will forward the devices to the Gira Service Center.  

Gira 
Giersiepen GmbH & Co. KG 

Elektro-Installations- 
Systeme 

Industriegebiet Mermbach 
Dahlienstraße 
42477 Radevormwald 

Postfach 12 20 
42461 Radevormwald 

Deutschland 

Tel +49(0)21 95 - 602-0 
Fax +49(0)21 95 - 602-399 

www.gira.de 
[email protected] 

82575902 

13.05.2011 

7/7 

DALI Tronic transformer 105 W 

Содержание DALI Tronic Trafo 105 W

Страница 1: ...the device or load These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 1 Fastening screws for terminal cover 2 Mounting holes 3 Te...

Страница 2: ...ghtness value Adjusting brightness with installation button Light is switched on o Make a long press on the installation button Light becomes brighter or dimmer as far as the respective limit value i...

Страница 3: ...must not be exceeded Do not fit in the vicinity of heat sources e g lamps o Loosen screws 1 and remove terminal covers 3 o Fasten transformer with screws through mounting holes 2 Connection instructi...

Страница 4: ...V F 2 1 5mm2 H05VVH2 F 2 0 75mm2 H05VV F 2 2 5mm2 NYM J 3 1 5mm2 NYM J 3 1 5mm2 NYM O 2 1 5mm2 NYM O 2 1 5mm2 NYM J 3 2 5mm2 Figure 3 Stripping lengths o Strip connecting cables according to specifica...

Страница 5: ...ng transformer with installation button Figure 5 Connection diagram with installation button i Illuminated installation buttons may only be connected if they have a separate N terminal i Connect all t...

Страница 6: ...ower loss max 6 W Power factor 0 95 Output voltage AC 11 8 V eff Ambient temperature 20 50 C Housing temperature 75 C tc Protection rating IP 20 Safety class II Primary side connection Single stranded...

Страница 7: ...ease submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward t...

Отзывы: