Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for all device channels. In the
"Off" setting, the device
cannot be reset to the factory
setting. 

Repeater mode

On, Off
Basic setting: Off

In addition to its other
functions, the device can be
used as a repeater. In the
"On" setting, the device
repeats all the received
telegrams.

Transmission mode

Single, Double
Basic setting: Double

The transmission of all
measured value telegrams is
repeated to guarantee
increased transmission
security (no unsecured
transmission). It is possible to
switch over to simple
transmission.

Settings, channel

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.

Transmit voltage

On, Off
Basic setting: On

Transmits the current voltage
value.

Transmit current

On, Off
Basic setting: On

Transmits the current current
value.

Transmit effective output

On, Off
Basic setting: On

Transmits the average
effective output. If negative
values are displayed, then
effective output is fed in, e.g.
via a photovoltaic system. 

Transmit apparent output

On, Off
Basic setting: On

Transmits the current
apparent output value.

Transmit idle output

On, Off
Basic setting: On

Transmits the current value of
the basic oscillation idle
output. If negative values are
displayed, this is a capacitive
idle power. Positive values
show an inductive idle power. 

Transmit absolute effective
energy

On, Off
Basic setting: On

Transmits the cumulative
value of the effective energy. If
negative values are displayed,
then effective energy is fed in,
e.g. via a photovoltaic system. 

Effective energy

-1073741823…1073741823
Wh
Basic setting: 0 Wh (Current
value)

Displays the currently
cumulated effective energy.
The value can be reset to 0 or
set to any other value.

32582202

10499462

13.03.2014

4/7

eNet

Radio energy sensor, 1-gang intermediate plug

Содержание 5472 02

Страница 1: ...part of the eNet system High transmission reliability at a radio frequency of 868 MHz is achieved by the transmission behaviour and bidirectional data transfer The range of a radio system depends on...

Страница 2: ...alue effective output 1 W Transferred characteristic electric values Current Voltage Average effective output Interval for average formation configurable between 0 2 300 s Apparent output Fundamental...

Страница 3: ...e is reset to default setting 5 Appendix The icon confirms the conformity of the product to the relevant guidelines 5 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Rated load curren...

Страница 4: ...e current voltage value Transmit current On Off Basic setting On Transmits the current current value Transmit effective output On Off Basic setting On Transmits the average effective output If negativ...

Страница 5: ...transmission are often switch on and switch off operations In order to avoid incorrect measured values due to switch on peaks this parameter can be used to enter a suppression period The measured val...

Страница 6: ...ed effective energy Counter status can be set via settings window i The value can be updated using the arrow next to the display values 5 3 Troubleshooting Negative effective output or energy values a...

Страница 7: ...Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 32582202 10499462 13 03 20...

Отзывы: