background image

-

Temperature-dependent sun protection possible

-

Scene buttons for sun protection and twilight

-

Brightness measurement via brightness sensor

-

Sends brightness values to the eNet server if brightness changes more than 50 %

-

Test operation for adjusting protection and temperature threshold

-

Solar-powered device

-

Integrated battery as energy store

Can be set with eNet server:
-

Operation locks

-

Behaviour of actuators when a scene is removed

Supplementary functions with eNet Server
-

Fully encrypted radio transmission (AES-CCM) from eNet Server software version 2.0

-

Update of the device software

-

Reading of error memory

Sun protection

The sun protection function allows automatic lowering of a blind/shutter in strong sunlight.
If a set sun protection value is exceeded for more than 2 minutes, the sun protection sensor
transmits the "Sun protection" scene and the blinds move to their previously-saved sun
protection position.
If the brightness falls below the set sun protection value for longer than 15 minutes, then the
blind/shutter will move upwards again. 

i

The active sun protection function can be disabled by manually moving the blind/shutter.
The blind/shutter is then no longer moved automatically when the sun protection value is
undershot.

i

It is only possible to integrate switching and dimming actuators into the sun protection with
the eNet server.

Sun protection, temperature-dependent

Temperature-dependent sun protection cab primarily be used in the colder months of the year.
The shading of the interior is triggered when the set temperature value is exceeded, in addition
to the sun protection value. After triggering the sun protection, the temperature evaluation is
deactivated.

Twilight

When darkness begins, the twilight function allows automatic lowering of a blind/shutter or
lighting switching. If the set twilight value is undershot for more than 4 minutes, the "Twilight"
scene is opened.
If the set twilight threshold is exceeded for approx. 15 minutes, the blind/shutter moves upwards
or the lighting switches.
To allow the blind/shutter to move upwards automatically, also at dawn, position the sun sensor
so that it is not in the shadow of the blind/shutter. 

4 Operation

i

Before each operation, remove the cover and then attach it again afterwards.

i

When operating with the eNet Server, operation and signalling could vary from what is
described here.

Triggering a sun protection scene

o

Press the 

3

 (5) button.

The sun protection scene is opened, irrespective of the current brightness.

i

The sun protection is only lifted automatically when the sun protection value has been
exceeded for more than two minutes and then undershot.

Triggering a twilight scene

o

Press the 

2

 (4) button.

The twilight scene is opened, irrespective of the current brightness.

32582922

10864960

24.03.2017

2/7

Wireless Solar sun sensor

Содержание 5461 02

Страница 1: ...Solar cell on the rear 3 Button Prog 4 Twilight button 2 5 Sun protection button 3 6 Status LED 7 Sun protection adjuster 3 8 Twilight adjuster 2 9 Temperature adjuster C Position Off no temperature e...

Страница 2: ...into the sun protection with the eNet server Sun protection temperature dependent Temperature dependent sun protection cab primarily be used in the colder months of the year The shading of the interio...

Страница 3: ...ting and electrical connection Mounting of the sun sensor To ensure good transmission quality keep a sufficient distance from any possible sources of interference e g metallic surfaces microwave ovens...

Страница 4: ...e allocated to each actuator The presetting for blinds shutters is the bottom end position Actuators are connected to the scene i With shutter actuators the actual shutter movement time must be saved...

Страница 5: ...ield typ 100 m Receiver category 2 6 2 Parameter list The device parameters can be changed with the eNet server Device and channels Parameter name Setting options Basic setting Explanations Function O...

Страница 6: ...procedure with the eNet server Put sun sensor in a very bright place for several hours As soon as the energy store is sufficiently charged the device is operational again after pressing the Prog butt...

Страница 7: ...ions Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 32582922 10864...

Отзывы: