background image

System 3000

Blind timer and timer BT, Operating top unit BT

Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme

Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald

Postfach 12 20
42461 Radevormwald

Deutschland

Tel +49(0)21 95 - 602-0
Fax +49(0)21 95 - 602-191

www.gira.de
[email protected]

12 / 12

32598122

10868257

06.07.2022

Содержание 5367 Series

Страница 1: ...njuries fire or property damage possible Please read and follow manual fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit...

Страница 2: ...e green or orange LED Blue LED before red LED 3 Intended use Manual and time controlled operation of e g Venetian blinds shutters awnings lighting or fans Operation and programming with mobile end dev...

Страница 3: ...at sunrise and or before sunset Astro function Astro time through position fixing Astro time shift can be set for each switching time Automatic summer winter time changeover can be switched off Call f...

Страница 4: ...in the ventilation position when moving down see Saving the ventilation position When executing via a Bluetooth wall transmitter the blind shutter is activated as long as pressure is applied to the b...

Страница 5: ...r temperature After a further double click the device switches back to normal operation and signals this with a short switching off and on again After one minute without operation the device also retu...

Страница 6: ...tention if required A call can be triggered via a 2 wire extension Bluetooth wall transmitter or push button Precondition The call function has been activated via the app Press the button of the exten...

Страница 7: ...d consumer is obligated to return the device 11 Parameter list Adjustable parameters via app Depending on the insert the following parameters can be changed with the app Settings for switching dimming...

Страница 8: ...tion if required If the function is activated a call can be triggered via a 2 wire extension Bluetooth wall transmitter or push button If a call has been triggered the lighting flashes 1 second on 1 s...

Страница 9: ...ters Setting options Default setting Explanations Activating switch on delay for output 2 On Off Default setting On Switches the switch on delay for output 2 on and off If the parameter is switched of...

Страница 10: ...ss sensor Input MAC address After entering the MAC address the received brightness for the controller is used by bright ness dependent switching operations Brightness evalu ation On Off Default settin...

Страница 11: ...necessary for this func tion Action at dawn Depending on the insert used Switching dimming or moving the blind shutter The set value is called up when the twilight threshold value is exceeded E g the...

Страница 12: ...a Giersiepen GmbH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 19...

Отзывы: