System 3000 

RF operating top unit

RF operating top unit, 1-gang
Order no.: 5104 .., 5105 .., 5106 ..
RF operating top unit, 2-gang
Order no.: 5107 .., 5108 ..

Operating instructions

1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the device or load. In
so doing, take all the circuit breakers into account, which support dangerous voltages to the
device and or load.

The radio communication takes place via a non-exclusively available transmission path, and is
therefore not suitable for safety-related applications, such as emergency stop and emergency
call.

These instructions are an integral part of the product, and must remain with the end customer.

1 / 12

32403802

10867449

10.11.2021

Содержание 5104 005

Страница 1: ...w manual fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit breakers into account which support dangerous voltages to the...

Страница 2: ...Device components Front view 1 channel Figure 1 and 2 channel Figure 2 Figure 1 Device components 1 channel Figure 2 Device components 2 channel 1 Rockers 2 Status LED 3 Cover frame 4 System 3000 inse...

Страница 3: ...trans mitter 1 byte 2 bytes 3 bytes and 6 bytes brightness values temperatures calling up and saving of light scenes Operation in cabled KNX systems via media coupler see chapter Accessories Operatio...

Страница 4: ...ration concept single area operation dual area operation Rocker function Each rocker can perform an indi vidual function Button function Two buttons above one another per form the same function Each b...

Страница 5: ...ased Move Venetian blind Long press on button Stop or adjust Venetian blind Short press on button Set value e g brightness or temperature setpoint Short press on button Open scene Short press on butto...

Страница 6: ...ce combination is not functional The insert cover align ment identifies this case as a swapping of the covers for example after renovating a room The insert cover alignment reports an error via the st...

Страница 7: ...ard configuration The device combination does not transmit RF telegrams The ETS can reset the device to the delivery state with the Unload device command Status LED in the delivery state The status LE...

Страница 8: ...netian blind or room temperature controller insert or 3 wire extension are mounted and connected properly see instructions of the relevant inserts The mains voltage has been switched off Fit the cover...

Страница 9: ...channel Figure 6 Activating programming mode 2 channel Precondition The device is connected and ready for operation Activate programming mode Press the top right button and bottom right button simulta...

Страница 10: ...mming is successfully completed the status LED carries out its parameterised function For Dimming The load must be connected before ETS commissioning Without a con nected load the ETS aborts the progr...

Страница 11: ...r reset restores the basic device setting physical address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS During secure operation A master reset deactivates d...

Страница 12: ...ld typ 100 m Receiver category 2 Ambient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Relative humidity max 93 no condensation Gira Giersiepen GmbH Co KG Elektro Install...

Отзывы: