background image

Operating system: Windows Embedded 

The operating system is based on Microsoft

®

 Windows

®

 XP Professional in a memory-optimised 

version. All the components required for the device function are preinstalled. Additional drivers 
or programs, e.g. Gira software package QuadClient, can be installed at any later time. 

4 Operation 

Cleaning the touchscreen 

The touchscreen requires regular cleaning in order to guarantee the optimum touch sensitivity. 
Keep the screen free of foreign bodies and dust. Use a soft, lint-free cloth to clean the screen. If 
needed, moisten the cleaning cloth slightly.  

Do not use sharp cleaning agents, acids or organic solvents. 

Keep moisture from penetrating into the device. Do not spray the cleaning agent directly 
onto the screen surface. 

Do not use sharp objects for cleaning. 

Removing the Design frame 

Certain operating elements are only accessible when the Design frame has been removed. 

Hold the bottom of the Design frame with both hands. 

Carefully push the Design frame upwards and to the first - upwards and left in the case of 
vertical mounting. 

When the Design frame is loose in the bracket, pull it carefully away from the wall. 

Mounting the Design frame 

Insert the Design frame into the brackets (3) in the right position. 

Carefully push the Design frame downwards until it engages. 

Switching a device on or off 

The On/off push-button (6) can be reached when the Design frame (1) has been removed. 

Switching on: Press the push-button (6). 
The panel switches on after about 2 seconds. 
The operating system is launched. 

Switching off: Press the push-button (6) briefly. 
- or - 

Press the "Start" button and select the "Shut Down" command in the Start menu. In the 
subsequent list box, select "Shut Down" again and press the "OK" button. 
The operating system shuts down and switches off. 

Alternatively, the device can be shut down into Standby mode. Operating the touchscreen 
immediately reactivates the function.  

When delivered, the device logs in automatically with the username 

Control 

 and the 

password 

Gira 

. Additional users can be added to the system at any time and the settings 

changed.  

Carrying out a reset 

If the panel can no longer be operated, e.g. after a program has crashed, then the device can 
be reset and switched off. Any unsaved data will be lost. 
The On/off push-button (6) can be reached when the Design frame (1) has been removed. 

Press the push-button (6) for approx. 5 seconds. 
The device switches off after about 5 seconds. 

Touch-sensitive surface 

The display screen features a touch-sensitive surface, the so-called touchscreen. The device is 
operated by touching the screen surface with a finger or a special touchscreen stylus (not 
included in the scope of delivery).  

Do not operate the screen with sharp or pointed objects. 

82576702 

15.11.2010 

3/10 

Control 9 Client 

Содержание 2078 00

Страница 1: ...sconnect device before working on it At the same time take into account all circuit breakers that supply dangerous voltage to the device Do not operate the device with sharp or pointed objects The tou...

Страница 2: ...oncealed mounting in interior areas flush to the wall in a Control 9 installation housing see Accessories chapter or with adapter frame in installation housing for information terminal Product charact...

Страница 3: ...rds until it engages Switching a device on or off The On off push button 6 can be reached when the Design frame 1 has been removed o Switching on Press the push button 6 The panel switches on after ab...

Страница 4: ...ected to the USB interface File based write filter The device contains a hard drive SSD as a mass storage facility To prevent unauthorised changes to the configuration the drive is protected by a file...

Страница 5: ...programs take the system requirements of the programs into account o Deactivating write filters select the icon 28 with the mouse pointer o Select the menu item Write protection The window for the wr...

Страница 6: ...g and connecting the device Figure 5 Rear side Connections 31 Connection for future expansion 32 Ethernet connection 33 Mains connection 34 Ventilation openings 35 Connection for Audio input and outpu...

Страница 7: ...en live parts are touched The mains voltage and low voltage are located in a shared appliance box If there is an error other connected components may carry mains voltage Electrical shocks can be fatal...

Страница 8: ...adapter plug To do this strip the Ethernet wires do not skin and insert into the cover of the adapter plug Shorten any wires that are jutting out and push the cover onto the adapter plug in the correc...

Страница 9: ...pe A 2 back 1 front Programming interface Connection Mini USB type AB 5 pole Network Type 10 100 MBit s Ethernet Connection RJ45 socket 8 4 pin Dimensions Dimensions WxHxD 283 117 65 mm without design...

Страница 10: ...nstallations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 399 www gira de info gira de 825767...

Отзывы: