Figure 6: Ventilation openings, front side
Ensure sufficient cooling. Do not cover the ventilation openings on the front and rear side of the
appliance box (Figure 6).
o
Install the panel-mounted housing in the correct position - horizontally or vertically aligned
in the wall.
Horizontal mounting: observe the labelling
OBEN TOP
and
UNTEN BOTTOM
.
Vertical mounting: top side points to the left.
i
Observe the mounting instructions of the installation housing.
o
Pull the connecting cables through the designated bushings.
DANGER!
Electrical shock when live parts are touched. The mains voltage and low
voltage are located in a shared appliance box. If there is an error, other
connected components may carry mains voltage.
Electrical shocks can be fatal.
Always secure the mains voltage with the enclosed tube.
Run the cables so that low voltage wires are securely protected against mains
voltage.
o
Strip the mains voltage cable to the length of the enclosed tube.
o
Pull the supplied tube over the stripped mains voltage wires
L
and
N
.
o
Connect the mains voltage
L
and
N
to terminal (33).
o
Connect audio devices to terminal (35) (Figure 7).
o
Connection the video device to terminal (36) (Figure 7).
Figure 7: Connection assignment, audio and video connections
82576702
15.11.2010
7/10
Control 9 Client