GIRA
Info
Combination sensor
Installation Instructions
Combination sensor
9/06
Page 4 of 5
Specifications
Power supply
Sensor unit
(incl. heating):
24 V AC/DC +/15 %,
50/60 Hz
Max. current
consumption: 600
mA
Power consumption:
14.4 W max.
(sensors and heating)
Weather station current
loading: max.
28
mA
Connection
Connecting cable:
LiYCY, 6 x 0.25 mm
2
,
shielded
Length:
10 m, max. 50 m
Ambient conditions
Ambient temperature:
-40 °C to +60 °C, ice-free
Storage/transport
temperature:
-40 °C to +60 °C
Humidity: outside
the
building
Enclosure
Protective system:
IP 55 in working position as
per EN 60529
Protection class:
III
Dimensions
(diameter x height):
130 x approx. 200 mm
(without stainless steel
bracket)
Type of installation:
stainless steel bracket
on
mast
or
wall
Weight:
approx. 330 g (without
stainless steel bracket)
Sensor signals
Wind velocity
Measuring range:
1 ... 40 m/s
Accuracy: < 0.5 m/s,
-20 °C ... +60 °C
Precipitation
Measuring range:
precipitation yes/no
Sensitivity: fine
drizzle
Switch-on delay:
approx. 3 precipitation
particles
Switch-off delay:
approx. 2 minutes
Brightness
Measuring range:
0 ... 110 kilolux
Spectral range:
700 ... 1050 nm
Resolution: 10
bits
Cardinal points:
East, South, West
Twilight
Measuring range:
approx. 0 ... 674 lux
Resolution: 10
bit