background image

GIRA

Info

Combination sensor

Installation Instructions

Combination sensor

9/06

Page 4 of 5

Specifications

Power supply

Sensor unit 
(incl. heating):

24 V AC/DC +/15 %, 
50/60 Hz

Max. current 
consumption: 600 

mA

Power consumption: 

14.4 W max. 
(sensors and heating)

Weather station current
loading: max. 

28 

mA

Connection

Connecting cable: 

LiYCY, 6 x 0.25 mm

2

,

 

shielded

Length: 

10 m, max. 50 m 

Ambient conditions

Ambient temperature: 

-40 °C to +60 °C, ice-free

Storage/transport 
temperature: 

-40 °C to +60 °C

Humidity: outside 

the 

building

Enclosure

Protective system: 

IP 55 in working position as
per EN 60529

Protection class: 

III

Dimensions 
(diameter x height): 

130 x approx. 200 mm 
(without stainless steel
bracket)

Type of installation: 

stainless steel bracket 

on

 mast 

or 

wall

Weight: 

approx. 330 g (without

 

stainless steel bracket)

Sensor signals

Wind velocity

Measuring range: 

1 ... 40 m/s

Accuracy: < 0.5 m/s, 

-20 °C ... +60 °C

Precipitation

Measuring range: 

precipitation yes/no

Sensitivity: fine 

drizzle

Switch-on delay: 

approx. 3 precipitation 
particles

Switch-off delay: 

approx. 2 minutes

Brightness

Measuring range: 

0 ... 110 kilolux

Spectral range: 

700 ... 1050 nm

Resolution: 10 

bits

Cardinal points: 

East, South, West

Twilight

Measuring range: 

approx. 0 ... 674 lux

Resolution: 10 

bit