background image

11

Warranty

We provide a warranty as provided for by law.
Please send the unit postage free with a description of the defect to our 
central customer service via your specialised dealer:

Gira
Giersiepen GmbH & Co. KG
Service Center
Dahlienstraße 12
42477 Radevormwald
Federal Republic of Germany

Gira
Giersiepen GmbH & Co. KG
Electrical Installation Systems
P.O. Box 1220
D-42461 Radevormwald
Phone: +49 2195 / 602 - 0
Fax: +49 2195 / 602 - 339
www.gira.com
[email protected]

Содержание 0389 Series

Страница 1: ...Operating Instructions Room temperature controller with clock 0389 ...

Страница 2: ... to the lowering temperature 5 Switching for longer periods to the lowering temperature 5 Deactivating the lowering temperature 5 Setting the individual temperature 6 Deactivating the individual temperature 6 Locking buttons 6 Settings in the program menu 7 How to access the menu items in the program menu 7 Setting the date and time Uhr menu item 7 Modifying temperature steps tEMP menu item 8 Modi...

Страница 3: ...ed here 2 Symbol for the Time program operating mode 3 Symbol for the Comfort temperature operating mode 4 Symbol for the Lowering temperature operating mode 5 Symbol for the Anti freeze temperature operating mode 6 The respective current operating mode is indicated here by means of triangles 7 The ranges set for the comfort temperature in the time program are displayed here 8 or button also calle...

Страница 4: ...on for the first time as well as after long deactivation periods e g after a power failure the room temperature controller jumps automatically to the time input the current data has to be entered here you can edit these data later for further information please refer to Setting the date and time Uhr menu item on Page 7 The hour display flashes 1 Press the or button until the desired hour has been ...

Страница 5: ...temperature for brief or long term periods of absence by means of the economy button Switching for brief periods to the lowering temperature 1 Press the button for less than 5 seconds The room temperature controller switches over to the lowering temperature The Lowering temperature mode is displayed This changeover is retained until the next switching time in the time program Switching for longer ...

Страница 6: ...there is valid Deactivating the individual temperature You can deactivate the individual temperature at any time 1 Press the P button in order to deactivate the individual temperature The room temperature controller returns to the normal time program Locking buttons To prevent accidental or unauthorised operation of the room temperature controller you can activate the button locking function in th...

Страница 7: ...d to carry out the further settings These are Minutes the time is set after confirmation with the S button Calendar year Month Day only enter the date here The weekday does not have to be entered since it is calculated automatically from the entered date 5 Confirm each entry with the S button After the last confirmation with S the system returns automatically to the program menu 6 Press the P butt...

Страница 8: ...saved 2 Press the P button in order to return to the normal view Modifying the time program ProG menu item You can change the switching times of your room temperature controller in the ProG menu item A maximum of 32 switching times are available Each switching time specifies a point within a week at which a change between the comfort and lowering modes takes place You can change the time in steps ...

Страница 9: ... the desired switching time 3 Press the and buttons for longer than 5 seconds The switching time is deleted irrevocably and the chronologically next switching time is displayed Deleting all switching times With this function you can delete all stored switching times This can for example be practical when a complete changeover of the time program is to be carried out and the deleting of individual ...

Страница 10: ...ming switching times If no further switching time is available no empty switching time is offered If a group of days is programmed and insufficient switching times are free FULL is output and the number of free switching times is displayed You then have to decide whether you want to remove enough switching times or whether you want to implement the desired program by using individual days If a gro...

Страница 11: ...o set the day 6 Press the S button again The display changes to the holiday end The month is displayed flashing 7 Use the same procedure to set the holiday end month and day 8 Confirm each entry with the S button The operating mode display begins to flash 9 Press the or button in order to select the desired temperature step which is to be maintained during the holiday All three temperature steps C...

Страница 12: ...er returns to the normal view After the anti freeze function has been deactivated the room temperature controller returns to continuous Lowering mode Proceed as follows in order to return to the normal time program 1 In normal display press the P button at least 5 seconds in order to access the program menu 2 Press the or button in order return to the ProG menu item 3 Press the S button in order t...

Страница 13: ...to our central customer service via your specialised dealer Gira Giersiepen GmbH Co KG Service Center Dahlienstraße 12 42477 Radevormwald Federal Republic of Germany Gira Giersiepen GmbH Co KG Electrical Installation Systems P O Box 1220 D 42461 Radevormwald Phone 49 2195 602 0 Fax 49 2195 602 339 www gira com info gira com ...

Страница 14: ...Mounting Instructions and Commissioning for the Electrician Room temperature controller with clock 0389 41 01 27 02 09 ...

Страница 15: ...p basic setting 6 Normal display n 7 Operating mode b 7 Differential gap d 7 Limiting temperature G 7 Temperature at the external sensor F 7 Minimum ON period t 8 Sensor offset o 8 Heating optimisation E 8 Gradient for heating optimisation r 8 Summertime regulation S 8 Accuracy U 9 Software version 9 Resetting all the settings Reset 9 Technical data 10 Acceptance of guarantee 11 ...

Страница 16: ...ice with an integral clock which can activate a temperature or time controlled switching relay and thus switch electrical loads on or off with a maximum current of 8 A cos ϕ 1 or 4 A cos ϕ 0 6 Temperature measurement can be implemented optionally via an integrated detector or an optional external detector i Note Information on the economical use of the room temperature controller is identified by ...

Страница 17: ...or conduit causing the sensor to be damaged Mounting The room temperature controller can be inserted or mounted into flush mounting boxes Please observe the following points for optimal operation We recommend an optimum mounting height of 1 50 m Do not subject the room temperature controller to direct sun irradiation or use it in the area of draughts or other temperature influenced air such as ove...

Страница 18: ...e underplaster unit of a Gira blinds control system When used incorrectly the room temperature controller displays the text FAIL flashing Failure at the external sensor With use of an external sensor this is tested for correct functionality If the sensor is defective or the supply cable is interrupted or short circuited FAIL appears in the display For more accurate error determination please contr...

Страница 19: ...ormal time program i Important information on changes in the parameter menu Changes in this menu should only be carried out by qualified persons since incorrect settings may result in proper control operation no longer being possible n normal Normal display time setpoint temperature actual temperature b operation Operating mode internal sensor external sensor or internal sensor with limit d diff D...

Страница 20: ...This parameter allows the setting of an individual limitation of the floor temperature If the limiting function is activated operating mode with limiting function selected the relay is deactivated as soon as the temperature measured at the external sensor exceeds the temperature set here heating In cooling mode the relay is deactivated as soon as the measured temperature lies below the set limitin...

Страница 21: ...F here If the heating optimisation is deactivated switching is carried out exactly as specified in the time program 1 The button can be used to set the heating optimisation to On and the button to OFF 2 S saves the setting The heating optimisation is activated On in our works Gradient for heating optimisation r The current gradient which is used to calculate the derivative action time can be check...

Страница 22: ...ing all the settings Reset You can delete all the parameter settings and programming and reset the device to the standard factory values 1 Keep the and buttons pressed simultaneously for longer than 10 seconds in the normal display The controlling device then carries out its display test and offers the clock setting for commissioning i Specifying the software version When reporting technical probl...

Страница 23: ...least 4 hours via Gold Cap capacitor no battery Operating voltage 230 V AC 50 Hz Power consumption Approx 3 7 VA Contact type 1 NO contact with equipotential bonding relay contact Max permissible switched current 8 A cos ϕ 1 4 A cos ϕ 0 6 Electrical endurance Min 5 x 104 switching cycles Minimum ON period 20 s to 500 s Increment 10 s Deadlock protection After 7 days of non operation of the relay a...

Страница 24: ...to our central customer service via your specialised dealer Gira Giersiepen GmbH Co KG Service Center Dahlienstraße 12 42477 Radevormwald Federal Republic of Germany Gira Giersiepen GmbH Co KG Electrical Installation Systems P O Box 1220 D 42461 Radevormwald Phone 49 2195 602 0 Fax 49 2195 602 339 www gira com info gira com ...

Отзывы: