![Giorik Steambox Evolution SEHE Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/giorik/steambox-evolution-sehe-series/steambox-evolution-sehe-series_installation-operation-and-maintenace-manual_2228800016.webp)
16
the values prescribed� When the appliance is installed under the extraction
hood, check that the following indications are respected:
a)
the volume extracted must be higher than that of the flue gases
generated (see current regulation);
b)
the material with which the hood filter is made must resist the
temperature of the flue gases which, on exiting the conveyor, can reach 300° C;
c)
the end part of the appliance evacuation pipe must be positioned
inside the base perimeter projection of the hood;
d)
the gas supply must be restored manually following a block caused by
insufficient suction.
1.9 Gas oven operating values (for gas versions only)
Model
SBHG061 SBTG061 SEHG101 SETG101 SEHG102 SETG102 SEHG201 SETG201 SEHG202 SETG202
Voltage
1N 230V
1N 230V
1N 230V
1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V
Frequency (Hz)
50
50
50
50
50
50
50
50
50
50
Absorbed power
(kW)
1�4
0�4
1�7
0�7
3�3
0�8
3�3
0�8
4�1
1�6
Nom� heat input (kW)
12
12
19
19
27
27
36
36
54
54
Section power
cable (mm
2
)
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
3 x 1�5
Nominal heat input
Gas consumption
SE
x
G061
SE
x
G101
SE
x
G102
SE
x
G201
SE
x
G202
G30 kg/h
0�94
1�49
2�13
2�84
4�26
G20 m
3
/h
1�26
2�01
2�86
3�81
5�71
G25 m
3
/h
1�47
2�33
3�32
4�43
6�65