GINA User’s Manual
Carrier Detect
CD=00
Carrier detector activates immediately every error
occurrence. This setting causes the CD line to drop
immediately if there is a dropout in the GINA to GINA
link up.
CD=01
Carrier detector holds 2 seconds every error occurrence.
This allows the CD link not to drop unless the GINA
link fade persists longer than 2 seconds.
RE Reset Command
RE=01
Resets unit to factory default settings.
TWICE
This command must be entered twice. The re-set must
TYPE
then be followed by configuring the channel using the
CH command.
After reset:
RC=03
For 2.4 Ghz GINA
Transmitter Power Code
The Transmitter Power Code command is operational and is slated for future
product development. It should be se to 01.
01 = Full Power 03 = 6db down
02 = 3db down 04 = 20db down
Remote Status
Allows over the air configuration of the remote’s status. Type the command to
change and use a colon (:) instead of an equal sign (=). For example: To
change the Carrier Detect Code, type: CD:01
Identification Code
The ID command is non-operational and is slated for future product
development. It should be set to 01.
1-6
©1999 GRE America, Inc. All rights reserved. This material is the property of GRE America, Inc. Copying or re-producing this
material is strictly prohibited. All violators shall be prosecuted to the fullest extent of the law.
1/99
Содержание 2000-64K
Страница 1: ...TM USER S MANUAL Model 2000 64K...