27
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH
EC DIRECTIVE 2012/19/UE-WEEE:
The symbol on the device indicates the separated collection of electric and electronic equipment. At
the end of life of the device, don’t dispose it as mixed solid municipal waste, but dispose it referring to a
specific collection centre located in your area or returning it to the distributor, when buying a new device
of the sample type to be used with the same functions.
Disposing of the product separately, avoids possible negative consequences for the environment and
health deriving from its inadequate disposal. This makes it possible to recover the materials of which it
is composed in order to obtain an important saving of energy and resources. The symbol on the label
indicates the separate collection of electrical and electronic equipment.
Caution: The wrong disposal of electric and electronic equipment may involve sanctions
GIMA WARRANTY CONDITIONS
Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the
material and the production. The warranty is valid for 12 months from the date of supply of GIMA.
During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to
production reasons. Labor costs and personnel traveling expenses and packaging not included. All components subject
to wear are not included in the warranty.
The repair or replacement performed during the warranty period shall not extend the warranty.
The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare
parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic
devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc.
The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed,
cancelled or changed. The defected products must be returned only to the dealer the product was purchased from.
Products sent to GIMA will be rejected.
Appendix
General Knowledge of ECG
Normal sinus rhythm
: In sinus conditions, S heart rate is in the
range of 60 to 100 times per minute and the rhythm is regular. P wave
is normal and each one is followed by a QRS wave. P-R interval:
0.12~0.20s;
QRS wave: 0.06~0.10s; No ectopic ECG activity.
Symptom: Sinus rhythm, heart rate: 60~100bpm
Indication: Normal
Several abnormal ECG waveforms
1)
Tachycardia
: The heartbeat becomes faster. Tachycardia is
determined by the rhythm of the heart, the average rhythm beats
faster than 100 times a minute is considered as Tachycardia. The
result description “Suspected fast beat” in this device may be doubted
as Tachycardia.
Symptom
: heart rate>100bpm
Indication
: It may occur with the normal people who have these physiology
conditions: rage, fatigue, smoking, drinking too much wine, excessive coffee and strong tea, etc.
Pathology
: anemia, Hyperthyroidism, blood hypoxia, myocarditis, hypokalemia, fever, influence of some medication
(such as atropine, epinephrine etc.).
Suggestion: If it belongs to pathology condition, please go to hospital.
2)
Bradycardia
: The heartbeat becomes more slowly. It is determined
by the rhythm of the heart, the average rhythm is less than 60 beats per
minute is considered as Bradycardia. The result description “Suspected
slow beat” in this device may be doubted as Bradycardia.
Symptom
: heart rate<60bpm
Indication
: It occurs when healthy people fall asleep, and it can be
found in athlete (or those who love doing sports frequently), old people,
or vagus excitement person.
Pathology
: Sick sinus syndrome, Ischemic heart disease,Cardiomyopathy, intracranial hypertension, increased hypokalemia,
Low temperature, period of convalescence of acute infectious disease or after use some medicines such as digitalis.
Suggestion: If it belongs to the pathology condition, please see the doctor.
ENGLISH