Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
7
Weight Mode Screen
In Weight mode, the feed rate is shown as a percentage. A range of 1-100% is available
with 100% being maximum feed rate. This rate is shown on the top line of the screen.
The operator can enter a target weight to feed out before the wagon floor will stop moving
and the system status will return to STOP.
(V3.9 onwards)
The operator can enter a target weight to feed out before a beeper will
sound and the wagon floor will stop moving and the system status will return to STOP.
(All)
The TO FEED value must be greater than zero else the system will not operate. Use
STANDARD mode for feeding if weight quantities are required.
Screen Features:
The top line shows the feed-out rate.
The second line shows the weight to feed out before a beeper sounds.
The third line shows the weight of the current load. This may be gross or tare.
The bottom line of the screen shows the status of the system (STOP), the mode of operation
(Weight), the battery voltage (highest voltage available to the unit. When disconnected from the
tractor, this will be the internal battery voltage), and connectivity status.
Operating Notes:
Screen Warnings:
“WAGON POWER NOT CONNECTED” will flash on the display if the GO button on the Remote
Display is pressed without the wagon being plugged into the tractor and/or power not getting from
the tractor to the Controller.
FEED RATE:
50%
TO FEED:
560kg
GROSS:
2950kg
STOP Weight 12.5V
Mode of operation
System status
System battery indicator
Feed Rate
Target weight to feed
Product weight in machine
Connectivity status
Battery voltage
The operator can alter the feed-out rate by adjusting the rate
percentage by pressing UP or DOWN on the keypad.
The operator can adjust the weight to be dispensed by adjusting the
‘TO FEED’ figure. This is done by pressing UP or DOWN on the
keypad when the ‘TO FEED’ figure is underlined. Use the RIGHT
or LEFT button to move the underline cursor.
The operator can start and stop the feed-out by pressing GO
and STOP on the keypad.
The operator can switch to other available operating modes
by pressing MODE on the keypad.
The operator can select between gross and tare weight to be
displayed by pressing TARE/GROSS on the keypad.
The operator can zero the gross and dispensed weight by
pressing ZERO on the keypad.