Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
16
Recommended Load Cell Bolt Torque Settings
M20 - 280 ft/lbs or 380Nm
M24 - 490 ft/lbs or 660Nm
Fitting the Load Cells
Fit the studs to the load cell first before fitting the load cells to the machine using the bolts
provided.
Lower the top half of the wagon onto the studs.
Tighten the top nut then back off ½ turn.
Route the wiring through the pipe/brackets provided through to the junction box taking
care to keep the wiring tidy and away from moving objects.
Note: If installing PT brand load cells, there will be two extra blue and brown
wires. Connect the Sense +ve (brown) together with Excive (red) and
Sense
–ve (blue) together with Excitation –ve (black).
Weight Module Connection
When fitting load cells or a wheel sensor, see below for fitting information about connecting
wires into the weight module.
Concave washer
Convex washer
Load cell
Stud and nut
Insert screw driver for top layer here
Top layer
Insert screw driver for bottom layer here
Bottom layer