Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
22
Factory Parameter Settings
Software Revision: Remote Display 3.4, Controller 3.8
To enter set-up, press TARE/GROSS and ZERO together for 4 seconds or until the set-
up screen appears.
Press MODE until the correct parameter is displayed.
Press UP or DOWN to adjust the parameter.
Press STOP to exit the configuration screens.
Remove power from the Controller to update changes.
Parameter
Value
Scale Damping Value
6.00
Load Cell Type
5000.00 kg
Number Of Load Cells
4.00
Load Cell Sens.
2.00 mV/V (PT) or 2.20mV/V (Kelba)
2.00mV/V (PT)
Scale Hysteresis
10.00 kg
Scale Increments
10.00 kg
Wheel Sensor Fitted
Yes
Wheel Diameter
760.00 mm
No. of Wheel Holes
15.00 or 23 (check)
Low Batt Level
11.50 V
Valve Fitted
Yes
Max Valve PSI
2250.00 psi
Min Valve Setting
30.00 %
Valve Ramp Up Time
0.00 sec
Valve Ramp Down Time
0.00 sec
Valve Startup Dist.
85.00 %
Speed Mode Min Speed
1.00 km/h
Speed Mode Max Speed
10.00 km/h
Speed Mode Strt Time
1.00 sec
Dist. Before Finish
1.00 m
Shut Down Timer
20.00 min
Note: These are factory default settings. Some machines will require different settings.