WARRANTY

Gilson warrants this pipette against defects in material under normal 
use and service for a period of 12 months from the date of purchase. 
This warranty shall not apply to pipettes which are subject to abnormal 
use and/or improper or inadequate maintenance (contrary to the 
recommendations given in the User’s guide), including, but not limited 
to pipettes which have been subjected to physical damage, improper 
handling, spillage or exposure to any corrosive environment. This war-
ranty shall also be void in the event pipettes are altered or modified 
by any party other than Gilson or its designates. Gilson’s sole liability 
under this warranty shall be limited to, at Gilson’s sole option, repair or 
replacement of any defective components of pipettes or refund of the 
purchase price paid for such pipettes.

THE FOREGOING WARRANTY IS EXCLUSIVE AND GILSON HEREBY 
DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, 
INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND ANY 
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, UNDER NO 
CIRCUMSTANCES SHALL GILSON BE LIABLE FOR ANY CONSEQUENTIAL, 
PUNITIVE, INDIRECT OR INCIDENTAL DAMAGES ARISING OUT OF ANY 
BREACH OF ANY EXPRESS OR IMPLIED WARRANTY.

EC DECLARATION OF CONFORMITY

MICROMAN® E 

M10E, M25E, M50E, M100E, M250E, M1000E

Positive displacement 

Capillaries/Pistons

98/79/EC

on In Vitro Diagnostic Medical Devices

 

comply with the requirements of the following European 
Directives:

Villiers-le-Bel, June 20

th

, 2014

 

E. Chamault 

H. Le Dorze

 

General Manager

 

Quality Manager

GILSON S.A.S.

 

19, avenue des Entrepreneurs

BP. 145 - 95400 Villiers-le-Bel (France)

Tel.: +33(0) 1 34 29 50 00 

Fax: +33(0) 1 34 29 50 20

www.gilson.com

* Annex III, self-declared

 

The company,

Hereby certifies under its sole responsibility that the products 
listed below:

Содержание MICROMAN E M1000E

Страница 1: ...Ergonomic Pipetting for Problem Liquids ...

Страница 2: ...hese are the only parts to be in touch with the aspiratedliquids andreplacementthereofwillprovide absolute protection against contamination caused by carryover between samples or reagents Simply replace the capillary and piston between assays they are ejected automatically and simultaneously thus avoiding any risk for the operator MICROMAN E is equipped with a direct reading volumeter that allows ...

Страница 3: ...ing a medical wipe or similar soft tissue CP Capillary Piston C P CP10 Polypropylene Polyester CP25 Polypropylene Polyester CP50 Polypropylene Polyester CP100 Polypropylene Polyethylene CP250 Polypropylene Polyethylene CP1000 Polypropylene Polyacetal 5 FITTING THE CAPILLARY AND PISTON 4 OPERATING RANGES AND MATERIAL Available Models Model Volume Range M10E 1 µL to 10 µL M25E 3 µL to 25 µL M50E 20 ...

Страница 4: ...lack or red to indicate the position of the decimal point according to the model see examples 3 2 MICROMAN E CP model CP10 M10E CP25 M25E CP50 M50E CP100 M100E CP250 M250E CP1000 M1000E CP10 CP25 CP50 CP100 CP250andCP1000Tipack Capillary pistons CP are deliveredreadytouse Tofit a capillary piston proceed as follows 1 Gently press the MICROMAN E onto the capillary piston until it is firmly seated o...

Страница 5: ... the capillary piston Press the push button to the first stop 1 then press down harder to the second stop 2 at this point the piston and capillary are ejected simultaneously MICROMAN E is automatically calibrated by correctly fitting a capillarypiston Once thevolumeisset measurementswillbe accurate and precise 8 GLP FEATURES No need to touch disposables capillary piston Serial Number engraved on p...

Страница 6: ...haft 3 Set aside the body handle in a dry and secure location 4 Clean the individual components using an ultrasonic bath for 20 minutes at 50 C or with a soft cloth and brush Small round brushes with soft plastic bristles may be used to clean the interior of the shaft 5 Rinse the individual components with distilled water 6 Leave the parts to dry by evaporation or wipe them down with a clean soft ...

Страница 7: ...sis of adjustment Ex Reference temperature 20 C Relative humidity 50 Barometric pressure 101 kPa Use of distilled water grade 3 ISO 3696 Ten measurements for each test volume which are nominal volume 50 of nominal volume and the minimum or 10 of nominal volume Performance Tests Eachpipetteisinspectedandvalidatedaccordingtothe Gilson Quality Assurance System Based on extensive historicaldata manufa...

Страница 8: ...e purchase price paid for such pipettes THE FOREGOING WARRANTY IS EXCLUSIVE AND GILSON HEREBY DISCLAIMSALLOTHERWARRANTIES WHETHEREXPRESSORIMPLIED INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND ANY WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE UNDER NO CIRCUMSTANCESSHALLGILSONBELIABLEFORANYCONSEQUENTIAL PUNITIVE INDIRECTORINCIDENTALDAMAGESARISINGOUTOFANY BREACH OF ANY EXPRESS OR IMPLIEDWARRANTY E...

Страница 9: ...ilson Inc World Headquarters 3000 Parmenter Street I P O Box 620027 I Middleton WI 53562 0027 USA Tel 1 800 445 7661 or 1 608 836 1551 I Fax 1 608 831 4451 Gilson S A S 19 avenue des Entrepreneurs I BP 145 F 95400 Villiers le Bel France Tel 33 0 1 34 29 50 00 I Fax 33 0 1 34 29 50 20 www gilson com sales gilson com service gilson com training gilson com ...

Отзывы: