vii
Model: OVH-10-FB & 11-FB
Safety
• The electronic components of the Control Panel are somewhat impact-sensitive. Exercise due care to avoid pos-
sible unintentional damage.
• After cleaning the EAC cell,
DO NOT
attempt to dry it by installing it in the hood and running the fan to force air
dry it, or by running the appliance under the hood to heat dry it. This could potentially damage the EAC power
supply and control system, leading to malfunction and voiding the warranty. The EAC filter must air dry at ambient
room temperature, preferably overnight.
• When cleaning the Hood and Hood Skirt:
••
DO NOT
steam clean.
••
DO NOT
spray with water from a hose.
••
DO NOT
use products containing chlorine or other caustic chemicals.
••
DO NOT
use abrasive products, steel wool or scouring pads.
• Failure to comply with these
CAUTION
notices may result in damage to equipment or property, and void the war-
ranty.
CAUTION
NOTE:
• Upon delivery, the palletized unit should have be thoroughly inspected. If damage is evident, the shipment should
have been refused and damages promptly reported to the freight company.
It is generally the customer’s
responsibility to negotiate freight damage claims.
• As an aid for electricians and installers, an electrical wiring diagram is provided with the unit. Refer to the wiring
diagram during installation or while servicing.
• Comply with all appropriate state and/or local heath regulations regarding cleaning and sanitation of foodservice
equipment.
• Giles recommends the use of mild, bio-degradable, non-toxic degreasers, such as
Clear Magic
or
Simple Green
,
for cleaning parts of the hood where excessive grease film accumulation is present.
• Always ensure the unit is installed and electrically grounded in accordance with local codes, or in the absence of
local codes, in accordance with the
National Electrical Code, NFPA 70
.
• The sound level of the hood while operating is approximately 65 dB.
•
During some installations, it may be necessary to consult a HVAC specialist to confirm
that proper room air exchange is occurring and that the on-site air conditioning system
is capable of handling anticipated heat load.
• Exhaust ventilation is recommended for areas in which recirculating hoods are operated. Giles recommends
50
CFM
per linear foot of hood space.
This amount could vary based on local codes and site-specific situations
.
Содержание OVH-10-FB
Страница 2: ......
Страница 4: ......
Страница 10: ...viii Model OVH 10 FB OVH 11 FB Safety ...
Страница 20: ...10 Model OVH 10 FB 11 FB Installation 2 04 2 Hood Appliance Wiring Configurations ...
Страница 22: ...12 Model OVH 10 FB 11 FB Overview ...
Страница 24: ...Overview Model OVH 10 FB OVH 11 FB 14 3 01 Control Panel 2 1 ILS Only Not Shown 6 5 3 4 8 7 ...
Страница 26: ...16 Model OVH 10 FB Overview 3 02 Hood Front Filter Chamber 1 4 3 2 5 6 ...
Страница 30: ...20 Model OVH 10 FB OVH 11 FB Overview NOTES ...
Страница 38: ...NOTES Operation Filter Maintenance Model OVH 10 FB 11 FB 28 ...
Страница 42: ...Notes Hood Cleaning Maintenance Model OVH 10 FB 11 FB 32 ...
Страница 52: ...42 Parts List NOTES Model OVH 10 FB 11 FB ...
Страница 53: ......