Gilbert 1999GT-230 Скачать руководство пользователя страница 15

2000GT

230

4582

5005

4526

4515

711

230

4601

4582

5009

4614

 4049

4528-S

4530-S

4010

4041

4514

6062

601T

230

4601

4582

5009

4614 

4048

4526

4536

4005

4031

4064

4514

6062

601E

230

4601

4582

5009

4614

4048

4526

4005

4033

4066

4514

705

230

4601

4582

5009

4614

4049

4528-S

4530-S

4010

4041

4514

6062

605

230

4601

4582

5009

4614

4049

4528-S

4530-S

4010

4039

4514

6062

220

230

4601

4582

5005

4614

 4049

4528-S

4530-S

4010

4041

4514

6064

6049

6062

1999GT

230

4582

5003

4526

4515

219GT

230

4582

5005

4528-S

4530-S

4043

4514

6064

6049

6062

747GT

230

4582

5009

4528-S

4530-S

4041

4514

6062

607

230

4601

4582

5009

4614

  4048

4528-S

4530-S

4005

4037

4514

6062

2002GT

230

4582

5005

4526

4515

225GT

230

4582

5005

4528-S

4530-S

4044

4514

6033

15

TROUBLESHOOTING GUIDE

All repairs must be performed by qualified personnel. Repair can be accomplished with a few simple tools.

Do not attempt any major repair without consulting the factory.

PROBLEM

PROBABLE CAUSE

CORRECTION

1.  Remove lamp from its socket. Reverse ends and replace in socket. (Turn lamp upside down).

1.  Not grounded.

1.  Check fuse or circuit breaker.
2.  Check connections from line cord.
3.  Repair or replace.
4.  Check actuator for proper closure on guard or tray.

1.  Not plugged in to a live receptacle.
2.  Loose connections.
3.  Faulty line cord.
4.  Interlock switch.

No lights or

voltage to

the grid.

Lamp Flickers

1.  Shorted grid wires.

2.  Loose connection.

3.  Faulty transformer.

1.  Disconnect power. Examine grid wires to verify that no two wires are touching each other.

     Be sure there is sufficient gap between two wires. Bend back into alignment.
2.  Disconnect power. (a) Make sure high-voltage leads are connected to the grid lugs. (b)

     Remove the unit's cover by drilling out rivets (on Model 601C-230 see specific instructions for

     removing inner-body on page 4). Check all connections to and from transformer then retest.
3.  Replace (See schematic).

Lights but

no voltage

to grid.

1.  Arc the grid with screwdriver.
2.  Check all sockets for proper seating and alignment.
3.  Replace.
4.  (a) Remove cover by drilling out rivets (on Model 601C see specific instructions for removing

     inner-body on page 4).  Check all connections to and from ballast.
5.  Replace.
6.  Replace ballast (see Schematic).

1.  Temp. under 50 degrees F.
2.  Lamps not seated properly.
3.  Cracked lamp socket.
4.  Loose connection.

5.  Burned out lamp(s).
6.  Faulty ballast.

No lights,

but voltage

to grid

(if one).

1.  Unplug unit and bend grid wires into alignment.
2.  Remove any and all material from grid or insulator(s).

3.  Unit specifically designed to operate on 230volt, 50HZ. Check line voltage.
4.  Check for hairline cracks or breaks. Replace if cracked.
5.  Allow unit to operate until dry. Intermittent arcing will continue until completely dry.

1.  Gap between grid wires is not sufficient.
2.  Foreign material stuck on grid or

     insulator(s).
3.  Excessive line voltage.
4.  Cracked insulator.
5.  Moisture.

Intermittent

or continous

arcing between

grid wires.

     

MODEL 

TRANSFORMER

BALLAST

LAMP

SWITCH

INSULATOR

LAMPHOLDER

LAMPHOLDER

GRID       

GUARD

DIFFUSER 

DEFLECTOR

CORD

HANDLE 

FEET

KNOB

TRAY PEG

PARTS LIST - 230V, 50HZ

See Reference Drawings For Parts Locations               

601GT

230

4582

5005

4528-S

4530-S

4021

4514

6062

Содержание 1999GT-230

Страница 1: ...ight traps have one such safety switch If lamp flickers try reversing the lamp s PROFESSIONAL FLYTRAPS Gilbert www gilbertinc com LIMITED 1 YEAR WARRANTY To the original purchaser of a new 230 volt Gilbert Insect Light Trap we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of one year from date of purchase ...

Страница 2: ...TION EXTERIOR FINISH GENERAL SPECIFICATIONS Underwriters LaboratorieslistedunitsdisplaytheU L trademarks and fully comply with standards established by O S H A U S D A and other inspection agencies Registered with the Environmental Protection Agency EPA Est 39032 AR 1 Each unit is equipped with the properly rated spectral energy lamp for maximum insect attractancy Lamp replacement should be the sa...

Страница 3: ...E 230 VAC 50Hz BLUE BROWN BLUE BROWN LINE INPUT 230 VAC BLUE BROWN LINE INPUT 230 VAC 230V AC 50Hz WH5 230 BLUE BROWN LINE INPUT 230 VAC WH5 230 Flying Insects are highly attracted to our trap designs and the lamps we have selected Coupled with good integrated management procedures Gilbert traps provide unequaled flying insect control And a few even provide beauty and style Good strategy emphasize...

Страница 4: ... mounted 6 to 12 above floor for best results To recess mount the Executive or Custom remove wing nut at bottom of inner body which contains all electrical components pull out bottom of inner body slide down and out Mount outer case permanently into wall Reverse process to insert inner body INSTALLATION INSTRUCTIONS 1 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED 2 USING...

Страница 5: ...514 4582 4601 6003 4526 2 5 MODEL Gilbert 601T 230 Don MODEL Gilbert 601E 230 Executive See Parts List Page 15 For Part Descriptions See Parts List Page 15 For Part Descriptions 4514 4601 4582 6003 4526 ...

Страница 6: ...S 1 THIS UNIT IS DESIGNED FOR INDOOR USE ONLY 2 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROP ERLY INSTALLED 3 USING A LEVELAND PENCIL DRAW A SRAIGHT 28 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 27 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTIN...

Страница 7: ... when there is not room for a low wall mounted trap Mount flush with ceiling or suspend from ceiling using eyebolts To replace lamps guard must be removed from tray side of trap by the removal of 4 screws MODEL Gilbert 607 230 Hall Stalker See Parts List Page 15 For Part Descriptions 7 Light traps will catch flies better when there is less sunlight to compete with Window tinting film will screen o...

Страница 8: ...VER 4528 S 2 6011 2 4601 4614 4582 WORKHORSE 5 4530 S 2 6005 2 5009 2 SEE DETAIL A 4010 2 4041 4 4049 4 6033 PLUNGE 6062 2 KNOB TRAY 6027 53 DIVIDER 2 DETAIL A GROUND TERMINAL 8 32x1 4 RHMS SECURED BY 8 32 HEX NUT BACK PANEL MODEL Gilbert 705 230 Night Hawk See Parts List Page 15 For Part Descriptions Place wall mounted traps down low to best catch day flying insects like the housefly Ceiling trap...

Страница 9: ...THE TWO PLASTIC ANCHORS PROVIDED BEFORE MOUNTING THE TWO SCREWS The Night Eagle features superior effectiveness against night flying insects especially those with large circular flight patterns This trap is most often used above and perpendicular to shipping recieving docks takecarenottolocateanytrapswhereadditionalinsects can be attracted into the facility Adding optional back reflector panel con...

Страница 10: ...als physical exclusion and the strategic installation in non public areas of more powerful ILTs are all part of a good integrated pest management solution Venus will catch flies better when there is less sunlight to compete with She will do her best as the sun goes down The useofwindow tinting filmcanreduce theattractiveness ofwindows and thereby increase the effectiveness of any ILT Though gluebo...

Страница 11: ...7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 16 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER 4 FOR VERTICALMOUNTING USINGALEVELAND PEN CIL DRAW A STRAIGHT 7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE ENDAND MARKACROSS THAT ...

Страница 12: ...LEVEL AND PENCIL DRAW A STRAIGHT 9 LINE FROM THE CORNER IN BOTH DIRECTIONS 32 57 ABOVE FLOOR MEASURE 9 13 16 FROM THE CORNER AND MAKE A CROSS MARK ON BOTH LINES MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER NOTE IF MOUNTING ON MASONRY USE A 3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND IN...

Страница 13: ...3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS PROVIDED BE FORE MOUNTING THE TWO SCREWS 4 USE AS FREE STANDING PORTABLE HANDLE AND 3 MAR RESISTANT FEET The 219GT 230 Sticky Tiger has key hole slots located on back for wall instal lation usually mounted approximately 24 above floor The Tiger may also be used as a free standing portable see Guerrilla porta...

Страница 14: ...E MOUNTING THE TWO SCREWS The 747GT 230 Sticky Bear features superior effectiveness for control of flies and other flying insects The Bear has key hole slots located on back for wall installation Generally speaking the lower any trap is placed the more effective it is against flies The Bear is normally mounted 24 above floor Two glueboards are normally placed in the catch tray of the trap 2 option...

Страница 15: ... wires are touching each other Be sure there is sufficient gap between two wires Bend back into alignment 2 Disconnect power a Make sure high voltage leads are connected to the grid lugs b Remove the unit s cover by drilling out rivets on Model 601C 230 see specific instructions for removing inner body on page 4 Check all connections to and from transformer then retest 3 Replace See schematic Ligh...

Отзывы: