READ THIS FIRST

Before use, inspect the unit for in transit damage. Report any dam-

age to the delivering carrier for immediate "claim for damage" to 

the unit. Before returning a unit for repair, notify your distributor or 

factory for return  authorization. Do not discard the box and packing 

material until you are certain the unit is in good working order.

                                    

PHONE 870-932-6070  FAX 870-932-5609

 Gilbert Industries, Inc.

5611 Krueger Drive, Jonesboro, Arkansas 72401 U.S.A.

When locating traps, remember that UV light will color-fade wall paper, 

fabrics, etc. Once installed, make sure the safety switch actuator is 

engaged by either closing the guard or securing the tray, depending 

on the particular model. All electrocuting light traps have one such 

safety switch. If lamp flickers, try reversing the lamp(s).

PROFESSIONAL FLYTRAPS

®

Gilbert

www.gilbertinc.com

LIMITED 1 YEAR WARRANTY

To the original purchaser of a new 230 volt Gilbert® Insect Light Trap, we 

warrant that we will replace or repair free of charge any part found by us to 

be defective in factory workmanship or material for a period of one year from 

date of purchase. This replacement or repair of defective parts shall constitute 

the sole and exclusive remedy of the original purchaser. THE FOREGOING 

WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER EXPRESS 

OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS, AND OF ANY OTHER OBLIGATION ON 

THE PART OF GILBERT INDUSTRIES, INC. IN NO EVENT SHALL GILBERT 

INDUSTRIES, INC. BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR 

INCIDENTAL DAMAGES, nor for damage due to accident, abuse, lack of 

reasonable care, normal wear, unauthorized repair or operation on a power 

source other than 230 volt, 50 Hertz. The provisions of this warranty shall be 

governed by and construed under the laws of the state of Arkansas.

Hg - LAMPS CONTAIN MERCURY

MANAGE IN ACCORD WITH DISPOSAL LAWS

See: www.lamprecycle.org or 1- 800-643-0400

Содержание 1999GT-230

Страница 1: ...ight traps have one such safety switch If lamp flickers try reversing the lamp s PROFESSIONAL FLYTRAPS Gilbert www gilbertinc com LIMITED 1 YEAR WARRANTY To the original purchaser of a new 230 volt Gilbert Insect Light Trap we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of one year from date of purchase ...

Страница 2: ...TION EXTERIOR FINISH GENERAL SPECIFICATIONS Underwriters LaboratorieslistedunitsdisplaytheU L trademarks and fully comply with standards established by O S H A U S D A and other inspection agencies Registered with the Environmental Protection Agency EPA Est 39032 AR 1 Each unit is equipped with the properly rated spectral energy lamp for maximum insect attractancy Lamp replacement should be the sa...

Страница 3: ...E 230 VAC 50Hz BLUE BROWN BLUE BROWN LINE INPUT 230 VAC BLUE BROWN LINE INPUT 230 VAC 230V AC 50Hz WH5 230 BLUE BROWN LINE INPUT 230 VAC WH5 230 Flying Insects are highly attracted to our trap designs and the lamps we have selected Coupled with good integrated management procedures Gilbert traps provide unequaled flying insect control And a few even provide beauty and style Good strategy emphasize...

Страница 4: ... mounted 6 to 12 above floor for best results To recess mount the Executive or Custom remove wing nut at bottom of inner body which contains all electrical components pull out bottom of inner body slide down and out Mount outer case permanently into wall Reverse process to insert inner body INSTALLATION INSTRUCTIONS 1 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED 2 USING...

Страница 5: ...514 4582 4601 6003 4526 2 5 MODEL Gilbert 601T 230 Don MODEL Gilbert 601E 230 Executive See Parts List Page 15 For Part Descriptions See Parts List Page 15 For Part Descriptions 4514 4601 4582 6003 4526 ...

Страница 6: ...S 1 THIS UNIT IS DESIGNED FOR INDOOR USE ONLY 2 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROP ERLY INSTALLED 3 USING A LEVELAND PENCIL DRAW A SRAIGHT 28 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 27 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTIN...

Страница 7: ... when there is not room for a low wall mounted trap Mount flush with ceiling or suspend from ceiling using eyebolts To replace lamps guard must be removed from tray side of trap by the removal of 4 screws MODEL Gilbert 607 230 Hall Stalker See Parts List Page 15 For Part Descriptions 7 Light traps will catch flies better when there is less sunlight to compete with Window tinting film will screen o...

Страница 8: ...VER 4528 S 2 6011 2 4601 4614 4582 WORKHORSE 5 4530 S 2 6005 2 5009 2 SEE DETAIL A 4010 2 4041 4 4049 4 6033 PLUNGE 6062 2 KNOB TRAY 6027 53 DIVIDER 2 DETAIL A GROUND TERMINAL 8 32x1 4 RHMS SECURED BY 8 32 HEX NUT BACK PANEL MODEL Gilbert 705 230 Night Hawk See Parts List Page 15 For Part Descriptions Place wall mounted traps down low to best catch day flying insects like the housefly Ceiling trap...

Страница 9: ...THE TWO PLASTIC ANCHORS PROVIDED BEFORE MOUNTING THE TWO SCREWS The Night Eagle features superior effectiveness against night flying insects especially those with large circular flight patterns This trap is most often used above and perpendicular to shipping recieving docks takecarenottolocateanytrapswhereadditionalinsects can be attracted into the facility Adding optional back reflector panel con...

Страница 10: ...als physical exclusion and the strategic installation in non public areas of more powerful ILTs are all part of a good integrated pest management solution Venus will catch flies better when there is less sunlight to compete with She will do her best as the sun goes down The useofwindow tinting filmcanreduce theattractiveness ofwindows and thereby increase the effectiveness of any ILT Though gluebo...

Страница 11: ...7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 16 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER 4 FOR VERTICALMOUNTING USINGALEVELAND PEN CIL DRAW A STRAIGHT 7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE ENDAND MARKACROSS THAT ...

Страница 12: ...LEVEL AND PENCIL DRAW A STRAIGHT 9 LINE FROM THE CORNER IN BOTH DIRECTIONS 32 57 ABOVE FLOOR MEASURE 9 13 16 FROM THE CORNER AND MAKE A CROSS MARK ON BOTH LINES MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER NOTE IF MOUNTING ON MASONRY USE A 3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND IN...

Страница 13: ...3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS PROVIDED BE FORE MOUNTING THE TWO SCREWS 4 USE AS FREE STANDING PORTABLE HANDLE AND 3 MAR RESISTANT FEET The 219GT 230 Sticky Tiger has key hole slots located on back for wall instal lation usually mounted approximately 24 above floor The Tiger may also be used as a free standing portable see Guerrilla porta...

Страница 14: ...E MOUNTING THE TWO SCREWS The 747GT 230 Sticky Bear features superior effectiveness for control of flies and other flying insects The Bear has key hole slots located on back for wall installation Generally speaking the lower any trap is placed the more effective it is against flies The Bear is normally mounted 24 above floor Two glueboards are normally placed in the catch tray of the trap 2 option...

Страница 15: ... wires are touching each other Be sure there is sufficient gap between two wires Bend back into alignment 2 Disconnect power a Make sure high voltage leads are connected to the grid lugs b Remove the unit s cover by drilling out rivets on Model 601C 230 see specific instructions for removing inner body on page 4 Check all connections to and from transformer then retest 3 Replace See schematic Ligh...