Installation
Page 12
MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010
6
For Q13698-03 power supplies:
• Connect the Q11121-01 Cable to the power supply.
• Plug cable into the power outlet.
For applications that do not have a National Electrical Manufacturer’s Association (NEMA)
5-15 style outlet, the customer must supply a connector and attach it to the end of a Q11736-01
Cable.
7
Turn on power to the Controller.
8
Verify the G-SITE system or third-party controller programming by checking for the
following:
• Correct addresses Poll/Cluster/Select.
• Correct number of Terminal IDs.
• Correct Terminal IDs.
• Correct Terminal address.
• Correct device type.
9
Contact the network for verification of parameters and station start up.
10
Observe the CRIND device display.
• If the CRIND device initiation is successful, you see a prompt requesting card insertion on
the display once the start up and initiation are complete.
• If the CRIND device displays OUT OF SERVICE or ONE MOMENT PLEASE, open the
• G-SITE POS system shift.
• If the CRIND device displays PLEASE PAY INSIDE and beeps, it implies that the
third-party controller is not polling the CRIND device.