MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010
Page 9
Installation
Installing the GSM
Verifying and Preparing for Installation
To verify and prepare for the installation of the GSM, proceed as follows:
1
Verify if the GSM to be installed displays the correct model number. The sticker placed on the
GSM indicates the oil company compatibility, which should match with the model number
code. For example, Shell
®
Oil Company GSM with PA02580000SHL.
Figure 1: Installing the GSM
Power Module Q12538-01
or Q13698-03 Part of
PA025800XXXXX
GSM Model No.
PA025800XXXXX
Isolated Ground Outlet POS
System CPU Controller Circuit
C-2 Controller PA0211XXXXXXX
Modular Cable 10’ (3.04 m) Long Q13850-10
(May not support all third-party controllers)
GSM Gender Mender
Q13180-04 or -04B
PC-based G-SITE POS System
GSM
Third-party
Controller*
I/O Expansion
Address 0
RS-232
5’
5’
* Refer to third-party documentation for installation of GSM with a third-party controller.
RS-232 Gender Mender
Q13180-22 or -22B
Q13180-20B COM
Gender Mender
Port 4
Passport
(Server)
USB-RS-232
Converter