Major Hardware Components
System Cables
Page 4-42 MDE-3664B TRIND® Start-up, Service, and Parts Manual · June 2013
Hand-held System Cable Connections on Encore 500 and Eclipse
Dispensers
Following table lists the Hand-held System Cable Connections on Encore 500 and Eclipse
Dispensers:
On Cable
Connect
To
On
M00515A002
J3110
P3110
CRIND Control Node PCA M00089
J250
P250
Gateway PCB T20678
M00811A001
P1
J1
M00806A001 Power Distribution Cable
3 Prong M
P3
3 Prong F, R20206 Power Input Cable
R20509-G2 (marked for Side A)
P1/2
J1
Side A Overhead Antenna (LF)
PA/B
*JA
Transmitter PCB Q13564
R20509-G2 (unmarked for Side B)
P1/2
J2
Side B Overhead Antenna (LF)
PA/B
*JB
Transmitter PCB Q13564
R20519-G1
J182
P182
Light/Micro Reader PCB Assembly T20182 on Side A Options Door
P7
*J7
DCB PCB Q13563
R20519-G2
J182
P182
Light/Micro Reader PCB Assembly T20182 on Side B Options Door
P8
*J8
DCB PCB Q13563
R20521-G1
J180
P180
Light/Micro Reader PCB Assembly T20182 on Side A Options Door
J177
*P177
Power supply PCB T20138
GRD
*Ground stud Card Cage
R20521-G2
J180
P180
Light/Micro Reader PCB Assembly T20182 on Side B Options Door
J176
*P176
Power supply PCB T20138
GRD
*Ground stud Card Cage
Q13578-01-01 (marked for side A)
P1
J1
Side A Overhead Antenna (HF)
P1
*J2B
Receive PCB
Q13578-01 (unmarked for Side B)
P1
J2
Side B Overhead Antenna (HF)
P1
*J2A
Receive PCB
Notes:
1. *Indicates connection point is on Card Cage assembly.
2. Route R20521-G1, R20521-G2, and R20437-G01 Cables through bottom of Card Cage to Side B for connections.
3. Check whether brand panel lighting ballast is connected to power supply. If so, disconnect ballast from power supply and terminate wires
ends according to NFPA 70, the National Electric Code and applicable local codes.