Capricorn MEC Outdoor CPE Installation Guide
DCP0000212(B)
Proprietary to Gilat Satellites Networks Ltd.
3
Connecting Grounding Cable
1.
Connect the grounding cable (GND) from the CPE to the approved site ground stud
using proper cable-lug and screw. Gilat recommends using the AWG 14 600V cable.
2.
Connect the grounding cable from the RF Lightning protection to the approved site
ground stud using proper cable-lug and screw. Gilat recommends using the AWG 14
600V cable.
Connecting LAN Cable
1.
Use only CAT-5 type cables to connect to the LAN port.
2.
Use only the Outdoor RJ45 LAN cable prepared according to Gilat instructions.
3.
Use the cable gland(s) provided with the kit to build and connect the cable.
Legend
Item
Qty
1
External Rubber Core Shell
2
2
Waterproof Circle 002
1
3
Rubber Core Shell
1
4
Screw Cap
1
5
Waterproof Rubber Plug
1
Figure 3: P2 Circular Male RJ45 Connector
Wiring List
P1
P2
Pin No.
Wire Color
Pair
Pin No.
Wire Color
Pair
1
White - Green
3
1
White - Green
3
2
Green
3
2
Green
3
3
White - Orange
2
3
White - Orange
2
6
Orange
2
6
Orange
2
4
Blue
1
4
Blue
1
5
White - Blue
1
5
White - Blue
1
7
White - Brown
4
7
White - Brown
4
8
Brown
4
8
Brown
4
Shield
Shield
Assembly Instructions
1.
Solder the LAN Cable Ground wire to both sides of the RJ45 connectors' shield.
2.
Depending on the cable width, use either a black rubber OD (5-6MM) or a red (7-
8.1MM) rubber plug.
3.
Perform the soldering of the shield to the internal side of the connector only.
4.
Use the standard cable testing equipment to verify that the wiring is correct.