background image

 

 

Capricorn MEC Outdoor CPE Installation Guide 

 

DCP0000212(B) 

Proprietary to Gilat Satellites Networks Ltd.  

Connecting Grounding Cable 

1.

 

Connect the grounding cable (GND) from the CPE to the approved site ground stud 

using proper cable-lug and screw. Gilat recommends using the AWG 14 600V cable. 

2.

 

Connect the grounding cable from the RF Lightning protection to the approved site 

ground stud using proper cable-lug and screw. Gilat recommends using the AWG 14 

600V cable. 

 

Connecting LAN Cable 

1.

 

Use only CAT-5 type cables to connect to the LAN port.  

2.

 

Use only the Outdoor RJ45 LAN cable prepared according to Gilat instructions.  

3.

 

Use the cable gland(s) provided with the kit to build and connect the cable. 

 

 

 

 

 

 

Legend 

Item 

Qty 

External Rubber Core Shell 

Waterproof Circle 002 

Rubber Core Shell 

Screw Cap 

Waterproof Rubber Plug 

Figure 3: P2 Circular Male RJ45 Connector 

 

Wiring List 

 

P1 

P2 

Pin No. 

Wire Color 

Pair 

Pin No. 

Wire Color 

Pair 

White - Green 

White - Green 

Green 

Green 

White - Orange 

White - Orange 

Orange 

Orange 

Blue 

Blue 

White - Blue 

White - Blue 

White - Brown 

White - Brown 

Brown 

Brown 

 

Shield 

 

 

Shield 

 

 

Assembly Instructions 

 

1.

 

Solder the LAN Cable Ground wire to both sides of the RJ45 connectors' shield. 

2.

 

Depending on the cable width, use either a black rubber OD (5-6MM) or a red (7-

8.1MM) rubber plug. 

3.

 

Perform the soldering of the shield to the internal side of the connector only.  

4.

 

Use the standard cable testing equipment to verify that the wiring is correct. 

 

 

Отзывы: