Capricorn Outdoor CPE Installation Guide 

 

Proprietary to Gilat Satellites Networks Ltd. 

DCP0000212(B) 

 

Preparing for Installation 

 

 

C

AUTION

 

 

T

HE 

CPE

 MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END 

OF THE GROUNDING CABLE TO THE GROUNDING STUD ON THE FRONT OF THE 

CPE,

 

AND THE OTHER END TO THE SITE MAIN GROUND CONNECTION

.

 

14AWG

 GROUNDING 

CABLE SHOULD BE USED

 

T

HE 

CPE

 MUST BE CONFIGURED PRIOR TO ATTACHING THE 

RF

 CABLES

 

T

HE POWER CABLE MUST BE DISCONNECTED FROM THE 

CPE

 PRIOR TO 

CONNECTING THE 

RF

 CABLES

.

 

 

 

 

 

C

AUTION

 

I

N ORDER TO PREVENT DAMAGE TO THE 

RF

 

C

ONNECTORS

,

 SECURE THE CABLES TO 

A PERMANENT

,

 STATIC OBJECT SUCH AS A TABLE OR PIPE

,

 AT A DISTANCE OF 

25-60

 

CM 

(10-25

 IN

.)

 FROM THE 

CPE,

 PRIOR TO CONNECTION

.

 

 

 

Connecting RF Cable 

1.

 

Connect the RF Lightning protection with the two RF cables (CB018520) to the 

RF 

IN

 and 

RF OUT

 ports of the modem (as shown in the figure below). 

 

 

Figure 2: Capricorn MEC Outdoor – Connecting RF Lightning Protection 

2.

 

Connect the two RF cables, from the Transceiver, to the RF Lightning protection 

respectively, using a recommended torque of 13 lbft/in (1.5 N/m). Use only the RF 

cables approved by Gilat.

 

 

 