20
you can check group 0
G00
to see if any ports are left out for setting.
6.5
Speed,Duplex,Flow Control Setting
6.5.1 802.3x Flow Control Setting (Port Base)
Specify IEEE 802.3x Flow-Control mechanism for each port.
Enable 802.3x Flow-Control:
IEEE 802.3x Flow-Control can avoid lost packets due to traffic congestion on
egress ports.
Default:
setting
Enable
and all port in
IEEE 802.3x Flow-Control
.
6.5.2 Speed and Duplex Setting (Port Base)
Each port can operate in Auto Negotiation mode and force mode, i.e.
100Mbps/Full duplex, 100Mbps/Half duplex, 10Mbps/Full duplex, and
10Mbps/Half duplex.
Speed/Duplex setting:
You can specify the speed and duplex setting manually for each port if
necessary. Usually
Auto
is OK, only when the port connected to other side of
device which is set to forced mode, you need to specify the match setting for
the port.
Default:
setting all port in
Auto-Negotiation mode
.
Note:
a. If the port set to forced mode, the IEEE 802.3x Flow-Control will be
inactive.
b. If the Switch has 100BASE-FX fiber port; the fiber port will only support
force to 100Mbps Half-Duplex or 100Mbps Full-Duplex mode.
Default:
setting
100Mbps Full-Duplex mode
.