- 23 -
System Appearance
2-6 Power Supply Unit LED
PSU LED
State
Description
Off
No AC power to all power supplies
GREEN
Output ON and OK
1Hz Blink GREEN
AC present/ only standby on/ Cold redundant mode
2Hz Blink GREEN
Power supply F.W updateing mode
Green BLINKING
0.25 Sec./On
0.25 Sec./Off
2Hz
PSU Sleep Mode (cold Redundant/Offline mode)
Amber
AC cord unplugged or AC power lost; with a second
power supply in parallel still with AC input power
Power supply critical event causing shut down:
failure, OCP, OVP, Fan Fail, UVP
1Hz Blink AMBER
Power supply warning events where the
power supply continues to operate:
high temp, high power, high current, slow fan
Содержание S451-3R1
Страница 1: ...S451 3R1 Intel 4U 42 Bay Dual Processors Storage Server User Manual Rev 1 0...
Страница 15: ...15 Hardware Installation 1 3 System Block Diagram...
Страница 16: ...This page intentionally left blank...
Страница 24: ...This page intentionally left blank...
Страница 33: ...33 System Hardware Installation Pull Pull 4 5 Push Push 6...
Страница 34: ...System Hardware Installation 34 2 5 Hard Drive 1 2 3 5 4 6...
Страница 36: ...System Hardware Installation 36 2 2...
Страница 44: ...44 Motherboard Components This page intentionally left blank...
Страница 64: ...BIOS Setup 64 5 2 11 Intel R I210 Gigabit Network Connection...
Страница 66: ...BIOS Setup 66 5 2 12 VLAN Configuration...
Страница 72: ...BIOS Setup 72 5 3 1 Processor Configuration...