- 101 -
BIOS Setup
Parameter
Description
NBIO RAS Common Options
(continued)
System Hub Watchdog Timer
–
Enter a value. This value specifies the timer interval of the
SYSHUB watchdog timer in miliseconds.
SLINK Read Response OK
–
This value specifies whether SLINK read response errors are
converted to an Okay response. When this value is set to TRUE,
read response errors are converted to Okay responses with data
of all FFs. When set to FALSE read response errors are not
converted.
– Options available: Enabled/Disabled. Default option is Disabled.
SLINK Read Response Error Handling
–
This value specifies whether SLINK write response errors are
converted to an Okay response. When this value is set to 0, write
response errors will be logged in the MCA. When set to 1, write
response errors will trigger an MCOMMIT error. When this value is
set to 2, write response errors are converted to Okay responses.
– Options available: Enabled/Trigger MCOMMIT Error/Log Errors in
MCA. Default option is Log Errors in
MCA
.
Log Poison Data from SLINK
–
This value specifies whether poison data propogated from SLINK
will generate a deferred error. When this value is set to TRUE,
deferred errors are enabled. When set to FALSE, errors are not
generated.
– Options available: Enabled/Disabled. Default option is
Disabled
.
PCIe Aer Reporting Mechanism
– This value selects the method of reporting AER errors from PCI
Express. A value of 0 indicates that the hardware will report the
error through MCA. A value of 1 allows OS First handling of the
errors through generation of a system control interrupt (SCI). A
value of 2 provides for Firmware First handling of errors through
generation of a system management interrupt (SMI).
– Options available: OS First/MCA/Auto. Default option is
Auto
.
Edpc Control
– (0) Disabled; (1) Enabled; (3) Auto.
– Options available: Disabled/Enabled/Auto. Default option is
Disabled
.
NBIO Poison Consumption
– Options available: Auto/Enabled/Disabled. Default option is
Auto
.
Содержание R282-Z94
Страница 1: ...R282 Z94 AMD EPYC 7003 DP Server System 2U 24 Bay Gen4 NVMe User Manual Rev 1 0 ...
Страница 10: ... 10 This page intentionally left blank ...
Страница 16: ... 16 Hardware Installation 1 3 System Block Diagram ...
Страница 35: ... 35 System Hardware Installation 2 2 2 2 3 3 ...
Страница 36: ...System Hardware Installation 36 4 5 6 7 5 5 4 4 7 7 6 6 ...
Страница 43: ... 43 System Hardware Installation Onboard SATA Cable NVMe Card Power Cable 3 12 Cable Routing ...
Страница 44: ...System Hardware Installation 44 CNV3022 CNV3132 NMVe Card 0 3 Cable NMVe Card 4 5 Cable CNV3134 ...
Страница 45: ... 45 System Hardware Installation CNV9134 NMVe Card 6 7 Cable NMVe Card 8 11 Cable CNV3022 CNV3132 ...
Страница 46: ...System Hardware Installation 46 CNV3132 NMVe Card 12 15 Cable NMVe Card 16 17 Cable CNV3134 ...
Страница 47: ... 47 System Hardware Installation CNV3132 CNV3022 NMVe Card 18 19 Cable Onboard NMVe Cable 20 21 Cable ...
Страница 48: ...System Hardware Installation 48 CNVP143 NMVe Card 22 23 Cable Rear HDD Backplane Board Power Cable ...
Страница 49: ... 49 System Hardware Installation Rear HDD Backplane Board Signal Cable HDD Backplane Board Power Cable ...
Страница 50: ...System Hardware Installation 50 HDD Backplane Board Signal Cable Front Panel USB 3 0 Ports Cable ...
Страница 51: ... 51 System Hardware Installation Front Panel LEDs and Buttons Cable ...
Страница 52: ...System Hardware Installation 52 This page left intentionally blankThis ...
Страница 56: ...Motherboard Components 56 This page left intentionally blankThis ...
Страница 73: ... 73 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Страница 78: ...BIOS Setup 78 5 2 11 SATA Configuration ...
Страница 83: ... 83 BIOS Setup 5 2 16 Intel R I350 Gigabit Network Connection ...
Страница 85: ... 85 BIOS Setup 5 2 17 VLAN Configuration ...