- 46 -
BIOS Setup
(Note) Advanced items prompt when this item is defined.
Parameter
Description
COM1/Serial Over LAN &
COM2 Console Redirection
Settings (continued)
Parity
– A parity bit can be sent with the data bits to detect some
transmission errors.
– Even: parity bit is 0 if the num of 1's in the data bits is even.
– Odd: parity bit is 0 if num of 1's in the data bits is odd.
– Mark: parity bit is always 1. Space: Parity bit is always 0.
– Mark and Space Parity do not allow for error detection.
– Options available: None, Even, Odd, Mark, Space. Default setting
is
None
.
Stop Bits
– Stop bits indicate the end of a serial data packet. (A start bit
indicates the beginning). The standard setting is 1 stop bit.
Communication with slow devices may require more than 1 stop
bit.
– Options available: 1/2. Default setting is
1
.
Flow Control
–
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can
be sent to stop the data flow. Once the buffers are empty, a 'start'
signal can be sent to re-start the flow. Hardware flow control uses
two wires to send start/stop signals.
– Options available: None, Hardware RTS/CTS. Default setting is
None
.
VT-UTF8 Combo Key Support
– Enable/Disable the VT-UTF8 Combo Key Support.
– Options available: Enabled/Disabled. Default setting is
Enabled
.
Recorder Mode
(Note)
– When this mode enabled, only texts will be send. This is to capture
Terminal data.
– Options available: Enabled/Disabled. Default setting is
Disabled
.
Resolution 100x31
(Note)
– Enable/Disable extended terminal resolution.
– Options available: Enabled/Disabled. Default setting is
Enabled
.
Putty KeyPad
(Note)
– Selects FunctionKey and LeyPad on Putty.
– Options available: VT100, LINUX, XTERMR6, SC0, ESCN, VT400.
Default setting is
VT100
.
Содержание R272-Z34
Страница 1: ...R272 Z34 AMD EPYC 7002 UP Server System 2U 26 Bay Gen4 NVMe User Manual Rev 1 0 ...
Страница 10: ... 10 This page intentionally left blank ...
Страница 16: ... 16 Hardware Installation This page intentionally left blank ...
Страница 41: ...System Hardware Installation 40 NVMe Power Cable ...
Страница 45: ...Motherboard Components 44 This page intentionally left blank ...
Страница 56: ... 46 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration ...
Страница 65: ... 46 BIOS Setup 5 2 9 PCI Subsystem Settings ...
Страница 76: ... 46 BIOS Setup 5 2 18 Intel R I350 Gigabit Network Connection ...
Страница 78: ... 46 BIOS Setup 5 2 19 VLAN Configuration ...
Страница 81: ...BIOS Setup 80 5 2 21 MAC IPv6 Network Configuration ...