background image

041-03 - Gas fryers

8

Construction, equipment installed and
safety devices

Robust steel frame, with 4 legs (adjustable in height).
18/10 chrome-nickel steel outer panelling and tanks.
The oil is heated by means of stainless burners (2 per
tank), built to withstand thermomechanical stress.
The pilot burner has has adjustable injector.
The combustion chamber and flues are made of electro-
galvanised steel sheeting. 
The temperature is regulated by a static thermal valve
which regulates ignition and extinguishing of the burners.
The deep fryers are fitted with a safety thermostat; should
the oil temperature exceed the limit value, the gas flow is
automatically cut off.
The equipment type B, if not positioned under an exhaust
hood, requires a windproof device, type MITRACF and/or
MITRAKF. 
This device should be fitted as per the instructions (see
“Gas venting”).

Attention!

Activation of the safety thermostat means the applian-
ce is not working properly;  before using the appliance
again, call the service centre to carry out a careful
check of all functions.

ASSEMBLY

Location 

The appliance should be installed in a well ventilated
room, and if possible under a range hood. 
If possible, “A” type appliances should be placed under
an aspirator. Type “B” appliances must be fitted with an
anti-wind device.
The appliance can be installed on its own or alongside
other equipment. 
If the appliance is to be installed near inflammable walls, a
minimum distance of 50 mm around the sides and back
should be allowed. 
If this is impossible, take proper steps to ensure the instal-
lation is safe, such as fitting tiles or heat-reflecting material
to the walls.
Before connecting up the appliance to the gas supply,
check on the data plate that the appliance is fitted for the
type of gas available. 
If not, consult paragraph “Running the appliance on other
types of gas”, page 10.

Legal and technical requisites 

During assembly, the following legal and technical re-
quisites should be adhered to: 

- relevant national legislation; 

- local building and fire safety regulations; 

- worksheet “Technical rules for installing gas”; 

- worksheet  “Technical rules for LP gas”; 

- worksheet “Gas installations in industrial kitchens”; 

- industrial injury legislation; 

- local Gas Board regulations; 

- current CEI regulations. 

INSTALLATION

Assembly, installation and maintenance, i.e.: assembly,
connecting the gas supply, checking power rating, trans-
forming or adapting the appliance to run on other types of
gas, and commissioning, must all be done by contractors
authorised by the local Gas Board in accordance with lo-
cal and national legislation UNI-CIG 8723-7722-7723 law
46 and circular 68 with subsequent updates. 
Before doing anything else, seek advice from your Gas
Board. 

Installation procedure

To level the appliance correctly, adjust the height of the
four legs. 

Gas connection 

The R 1/2” gas off-take for models CFG15 - CFG15D and
R 3/4” for models KFG15 - KFG15D - KFG20 - KFG20D -
OPFG15 - OPFG15D - OPFG20 - OPFG20D on the ap-
pliance can either be permanently fixed to the mains or
made detachable using a standard adaptor. 
If flexible hose is used, it must be in stainless steel. 
After completing connection, check for leaks using a spe-
cial leak-detector spray. 

Gas venting 

For deep fryers of construction type “A”, connection to a
gas venting system is not required; for ventilation of the
premises where the appliance is installed, observe the
laws in force. 
Fryers type B cannot function without the windproof device
if not positioned under an exhaust hood. Standard pipes
must be used for the flue gas outlet connection, according
to the procedures laid down by the laws in force and any
other local regulations.
Combusted gases must be evacuated:

a)

by natural ascension to the outside through a chim-

ney;

b)

by mechanical extraction through a chimney to the

outside or directly outside;

c)

through suction hoods.

Fit the standard anti-wind device as follows:
- Place part (A) on the appliance and fix with the relative

OPERATING INSTRUCTIONS

Содержание CFG15

Страница 1: ...041_03 Installation operating and maintenance instructions 01 2006 GAS FRYERS COPYRIGHT 2004 GIGA GRANDI CUCINE SRL CFG15 CFG15D KFG15 KFG15D KFG20 KFG20D OPFG15 OPFG20 OPFG15D OPFG20D ...

Страница 2: ...hecking the primary air 10 Checking the functions 10 Note for the installer page 10 Running the appliance on other types of gas 10 Replacing the main burner nozzle 10 Replacing the pilot burner nozzle 10 Maintenance 10 Replacing parts 11 Gas valve 11 Safety thermostat 11 Burner 11 Thermocouple 11 Ignition plung 11 Electrical components 11 Using the appliance 12 Preparation for use 12 Filling the t...

Страница 3: ...52 5 52 5 13 5 1 100 2 140 465 220 211 50 295 G 400 280 2 700 G TS 50 875 1896 52 5 52 5 13 5 1 100 2 140 465 220 50 695 G 800 280 2 700 G TS TS T S TS TS S T CFG15 CFG15D G TS T S 1 2 gas connector Safety thermostat Technical data Oil drain ...

Страница 4: ...060 55 55 21 100 2 140 465 210 215 60 290 TS G 400 310 2 900 G 310 2 900 G TS TS TS 800 875 1850 55 55 21 290 TS 100 2 140 465 210 60 G 50 T S S T KFG15 KFG20 KFG15D KFG20D G TS T S 3 4 gas connector Safety thermostat Technical data Oil drain ...

Страница 5: ...03 Gas fryers 5 Dimensions 400 310 2 900 G 310 2 900 G TS TS TS 800 530 TS 210 OPFG15 OPFG20 OPFG15D OPFG20D G TS T S 3 4 gas connector Safety thermostat Technical data Oil drain 210 215 60 TS 530 T T S S S ...

Страница 6: ...Q2905 51BQ2905 2 CHARACTERISTICS OF THE APPLIANCES The instructions contained in this manual apply to our Gas deep fat fryer in the II2H3 category see table on page 7 The data plate is located on the front of the appliance and on the control panel It contains all necessary reference data such as the name of the manufacturer input pressure gas type setting etc 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31...

Страница 7: ...1 100 mm Main burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Nominal capacity Nominal capacity G20 G30 31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 2 2 0 952 0 655 2 x 160 2 x 110 Adjustable 20 2 2 1 904 1 310 4 x 160 4 x 110 Adjustable 2 x 20 2 2 1 270 0 873 2 x 185 2 x 120 Adjustable 20 2 2 2 540 1 746 4 x 185 4 x 120 Adjustable 2 x 20 CFG15 KFG1...

Страница 8: ...es During assembly the following legal and technical re quisites should be adhered to relevant national legislation local building and fire safety regulations worksheet Technical rules for installing gas worksheet Technical rules for LP gas worksheet Gas installations in industrial kitchens industrial injury legislation local Gas Board regulations current CEI regulations INSTALLATION Assembly inst...

Страница 9: ...the nominal power according to the agreed nozzles from 15 to 22 5 mbar for gases of the second family from 25 to 45 mbar for gases of the third family propane The appliance will not work outside the above pressure thresholds If you wish to check the nominal capacity further you may do so using a gas meter according to the so called volumetric method As a rule however it is sufficient to check that...

Страница 10: ...ghly checked Running the appliance on other types of gas When changing to another type of gas e g from natural to LP or to another gas group consult the TECHNICAL DATA table to determine the correct nozzles to use The nozzles for the main burners for different types of gas marked in 100ths of mm are in a case supplied with the appliance When the appliance has been transformed or adapted recheck it...

Страница 11: ... insert the new part Burner Fig 1 Unscrew nozzle 28 and nut 29 Loosen the screws 26 fixing the burner to the chamber Replace the burner Thermocouple 38 Fig 1 Unscrew the nipple fixing the thermocouple to the valve loosen the 2 screws 25 on the pilot burner and replace the thermocouple To simplify the operation and all those concerning the pilot burner screws 31 may be removed and the pilot burner ...

Страница 12: ...d above all the tank see paragraph Cleaning and maintenance Filling the tank Check that the oil drainage outlet is closed Fill the tank up to the maximum level mark with frying oil or liquid fat Turning on and off Fig 3 Turn on gas supply Lighting the pilot burner Press the button 14 and as the same time the piezoelec tric lighter 12 to light the pilot flame which can be seen through hole 10 after...

Страница 13: ...OF MAINTENANCE Warning Never clean the appliance with jets of water whether direct or pressurised Allow the machine to cool down before cleaning Giving the appliance a thorough clean every day after tur ning it off will keep it in perfect working order and make it last longer All steel parts should be cleaned with water and a deter gent using a damp cloth do not use abrasive substances or corrodin...

Страница 14: ...O MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED GIGA GRANDI CUCINE S r l Via Pisana 336 Loc Olmo 50018 SCANDICCI FI ITALY Tel 39 055 722 33 11 linee r a Fax 39 055 7310 056 www gigagrandicucine it info gigagrandidicucine it ...

Отзывы: