Giga-tronics GT-1000A Microwave Power Amplifier
Performance Verification
Operation Manual, Part Number 34672, Rev. C, March 2011
Page 15
Table 13: AC Fuse
AC Fuse
1
Operating Voltage
Fuse Voltage Rating
Current Rating
100 to 120 VAC
250 VAC
10 Amps
200 to 240 VAC
5 Amps
1
The fuse is a Normal-Blow, type-T fuse for both input voltage ranges.
Table 14: Additional Specifications
Additional Specifications
Parameter
Specification
Stability
Unconditionally Stable
Maximum Load VSWR
3:1
Harmonic Distortion
1
< -30 dBc typical
Spurious
1
< -60 dBc typical
Noise Figure
< 10 dB typical, < 14 dB maximum
1
Harmonics measured at +27 dBm output power. Spurious measured at -5 dBm input power level