7. Mounting the electronics
Use a Torx T6 screwdriver to attach the elec-
tronics with 2x 2.2x5mm screws. Make sure
that the connection terminals are at the top. The
max. tightening torque is 0.4Nm
8. Mounting the new LED module
Lay the cable over the module
If necessary, remove 19mm of cable insulation,
so that the cable cores are exposed.
The insulation of the cable cores are labelled
No. 1-4. Place the strands in the self cutting
terminals as shown in the illustration.
Press the cable cores into the self cutting ter-
minals with the caps. The caps must be remo-
ved afterwards.
cable sheath flush