24/32
01.09.21, Subject to alterations
Adjustment tables
24 Adjustment tables
Natural gas LL: H
i,n
= 9,3 [kWh/m
3
]
Burner output
MG3-ZM-L-LN
2.Stage 1. Stage
Boiler output
η
k = 92%
2.Stage
1. Stage
Position
air flap
2.Stage 1. Stage
P9
P1
Position
Mixing
head
Gas nozzle
pressure
2.Stage 1. Stage
Gas thoughput
2.Stage 1. Stage
[kW]
[kW]
[kW]
[kW]
[°]
[°]
[mm]
[mbar]
[mbar]
[m
3
/h]
[m
3
/h]
900
450
828
414
16
5,5
20
11,5
3,5
101,3
50,7
1100
550
1012
506
23
7,5
20
17
4,5
123,9
61,9
1300
650
1196
598
42
10
20
25,3
6,4
146,4
73,2
1400
750
1288
690
48
12,5
20
28
8
157,6
84,4
1600
850
1472
782
55
15
0
33,5
9,7
180,1
95,7
1800
950
1656
874
63
17,5
0
39
13,2
202,7
107,0
2100
1050
1932
966
72
20
0
44,5
16,4
236,4
118,2
2200
1150
2024
1058
80
23
0
50
19,7
247,7
129,5
2300
1250
2116
1150
90
25,5
0
55,5
23
259,0
140,7
Natural gas E: H
i,n
= 10,4 [kWh/m
3
]
Burner output
MG3-ZM-L-LN
2.Stage 1. Stage
Boiler output
η
k = 92%
2.Stage 1. Stage
Position
air flap
2.Stage 1. Stage
P9
P1
Position
Mixing
head
Gas nozzle
pressure
2.Stage 1. Stage
Gas thoughput
2.Stage 1. Stage
[kW]
[kW]
[kW]
[kW]
[°]
[°]
[mm]
[mbar]
[mbar]
[m
3
/h]
[m
3
/h]
900
450
828
414
16
5,5
20
9,0
2,7
90,6
45,3
1100
550
1012
506
23
7,5
20
13,3
3,5
110,8
55,4
1300
650
1196
598
42
10
20
19,8
5,0
130,9
65,4
1400
750
1288
690
48
12,5
20
21,9
6,3
141,0
75,4
1600
850
1472
782
55
15
0
26,2
7,6
161,1
85,6
1800
950
1656
874
63
17,5
0
30,5
10,3
181,2
95,7
2100
1050
1932
966
72
20
0
24,8
12,8
211,4
105,7
2200
1150
2024
1058
80
23
0
39,1
15,4
221,5
115,8
2300
1250
2116
1150
90
25,5
0
43,4
18,0
231,6
125,9