The instrument is programmed and controlled through a remote control with 4 keys, all of them with
double function. The instrument based on the operation in progress automatically executes the selec-
tion of one of the two functions.
To access the setup menu it is necessary to push the key number 1 and subsequently key number 4.
In general, the management of the programming menu is done by the keys number 4 and 3 to scroll
through the entries, the key number 1 to access the relative sub-menu or programmable parameter,
while with the key number 2 one leaves the menu or returns to the superior level.
Key
Function
1 + 4
Access to the setup menu (keys pressed in sequence)
2
Reset of the displayed value (gross weight/net weight)
3
Send data on serial if manual protocol is selected
4
Insert semi-automatic tare / cancel semi-automatic tare
Operational functions
Data setting
Restore the weight
This operation is executed to correct small shifts of the zero value of the scales.
The reset command of the gross weight is not executed under the following conditions:
Weight instable (the weight does not stabilize within 3 seconds from the reset command).
Gross weight, in respect to the initial zero taring, is higher (in positive or negative) by 2% of the ca-
pacity.
Auto-weighed tare (Autotare) in visualization of net weight
The autotare command will not be executed under the following conditions:
Weight instable (the weight does not stabilize within 3 seconds from the reset command).
Gross weight negative.
Gross weight superior in respect to the maximum capacity.
If the autotare is executed with gross weight = 0, any tare value is canceled
Pagina –