Technical specification
Power supply
24 V direct current ± 10 % protected against inversion of polarity.
Protection resettable fuse
Maximum power consumption
1 Watt
Insulation
Class II
Installation category
Category II
Storage temperature
-4 °F / 140 °F
Operating temperature
14 °F / 122 °F
Humidity
maximum 85% non-condensing
LED
2 LED with 3 mm (function status)
Keyboard
3 keys (behind red front cover)
Overall dimensions
4.33 x 4.72 x 0.90 in including terminal blocks
Installation
Support for DIN or OMEGA rail
Material of housing
Blend ABS/PC self-extinguishing
Wire connections
Removable screw terminals, pitch terminal blocks 5,08 mm
Load cells input
Maximum 4 load cells with 350 Ω in parallel (or 8 cells with 700 Ω)
Power supply cells
4 Volt direct current
Linearity
0,01 % of full scale
Internal resolution
16 – 24 bit
Temperature deviation
< 0,001 % of full scale/°C
Measuring range
From -2,6 mV/V to +2,6 mV/V
Digital filter
Selectable 0.1 Hz – 50 Hz
Weight decimals
from 0 to 3 decimal numbers
Calibration Zero and full scale
executable through buttons
Cell cable break check
always present
Analog exit in tension
± 10 V / ± 5 V
Resolution
16 bit
Calibration
digital through buttons
Impedance
≥ 10 kΩ
Linearity
0,03 % of full scale
Temperature deviation
< 0,002 % of full scale/°C
Analog exit in current
0 – 20 A / 4 – 20 mA
Resolution
16 bit
Calibration
digital through buttons
Impedance
≤ 300 Ω
Linearity
0,03 % of full scale
Temperature deviation
< 0,002 % of full scale/°C
Compliance to EMC norms
EN61000-6-2, EN61000-6-3
Compliance electric safety
EN61010-1