background image

F4 PLUS

UK

12

3 - INSTALLATION WARNINGS

4 - WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. 
Periodically  check  functioning  of  the  safety  devices. Any  repairs  must  be  carried  out  by  specialised  personnel 
using original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or 
lacking  experience  and  knowledge,  unless  appropriately  instructed.  Do  not  access  the  circuit  board  for 
adjustments and/or maintenance.

Before proceeding with installation, fit a differential magnetothermal switch with a maximum capacity of 10A 
upstream  of  the  system. The  switch  must  guarantee  omnipolar  separation  of  the  contacts  with  an  opening 
distance of at least 3mm.

To  prevent  possible  interference,  differentiate  and  always  keep  the  power  cables  (minimum  cross-section 
1.5 mm²) separate from the signal cables (minimum cross-section 0.5 mm²).

Make the connections referring to the following tables and to the screen-printing on the board. Be extremely 
careful to connect in series all the devices that are connected to the same N.C. (normally closed) input, and 
in parallel all the devices that share the same N.O. (normally open) input.

Incorrect installation or improper use of the product may compromise system safety.

Keep all the materials contained in the packaging away from children since they pose a potential hazard.

The manufacturer declines all responsibility for improper functioning of the automated device if the original 
components and accessories suitable for the specific application are not used.

When installation is complete, always carefully check proper functioning of the system and the devices used.

This  instruction  manual  addresses  professionals  qualified  to  install  “live  equipment”  and  therefore  requires 
good technical knowledge and installation in compliance with the regulations in force.

Maintenance must be carried out by qualified personnel.

Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.

The control unit described in this document may only be used for the purpose for which it was designed.

Check the intended end use and take all the necessary safety precautions.

Use of the products for purposes different from the intended use has not been tested by the manufacturer 
and is therefore on full responsibility of the installer.

Mark the automated device with visible warning plates.

Warn the user that children or animals should not play or stand near the gate.

Appropriately protect the dangerous points (for example, using a sensitive frame).

WARNING: IMPORTANT SAFETY INSTRUCTIONS.

It is important to follow these instructions to safeguard persons.
Keep this instruction manual.

Содержание F4 PLUS

Страница 1: ...I UK Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS F4 PLUS F4 PLUS AS05850 ...

Страница 2: ...IONI 1 CARATTERISTICHE TECNICHE F4 PLUS 230 Vac monofase 50 60 Hz 1o2 230 Vac 230 Vac 40W max 24 Vac 3W max Ad innesto 20 C 60 C 24 Vac 8W max Apparecchiatura elettronica per l automazione di un cancello a battente scorrevole porta basculante o barriera con unooduemotoria230Vac Apparecchiatura Alimentazione N motori Alimentazione motore Lampeggiante Lampada spia Ricevitore radio Temperatura di uti...

Страница 3: ... imballo non devono essere lasciati alla portata dei bambini in quanto potenziali fonti di pericolo Il costruttore declina ogni responsabilità ai fini del corretto funzionamento dell automazione nel caso non vengano utilizzati i componenti e gli accessori di propria produzione e idonei per l applicazione prevista Al termine dell istallazione verificare sempre con attenzione il corretto funzionamen...

Страница 4: ...N C M3 COM FCCM2 FCAM2 FCCM1 Ingresso finecorsa apre MOTORE 1 N C 17 Ingresso FOTOCELLULA N C 18 19 20 Ingresso START N A Uscita 24Vac per alimentazione FOTOCELLULE ACCESSORI MAX 8W FCAM1 PHOTO START 24Vac Uscita 0Vac per alimentazione FOTOCELLULE ACCESSORI ed ELETTROSERRATURA 21 Uscita 12Vac per ELETTROSERRATURA max 15W 22 23 24 Ingresso STOP N C SE DIP 11 IN OFF ingresso COSTA 8K2 SE DIP 11 IN O...

Страница 5: ...ndo viene raggiunto il FINECORSA DI CHIUSURAdelmotore1 FCCM1 L3 ROSSO Sempre acceso Si spegne quando viene raggiunto il FINECORSA DI APERTURAdelmotore1 FCAM1 L4 ROSSO Sempre acceso Si spegne quando viene intercettata la fotocellula interrompendoneilraggio PHOTO L5 VERDE Siaccendequandovieneattivatoilcomando diSTARTesispegnealrilascio START L6 ROSSO Sempre acceso Si spegne quando viene attivato ape...

Страница 6: ...Logica CONOMINIALE Funzionamento in risposta al comando di START ŸCancello chiuso APRE ŸDurante l apertura ININFLUENTE ŸCancelloaperto Ricarica il tempo di chiusura automatica se la richiusuraautomaticaèabilitataaltrimentichiude ŸDurante la chiusura APRE DIP 2 1_ LogicaPASSO PASSOCONSTOP FunzionamentoinrispostaalcomandodiSTART ŸCancellochiuso APRE ŸDurantel apertura STOP ŸCancelloaperto PAUSA ŸDur...

Страница 7: ...are i morsetti 28 29 per collegare un LAMPEGGIATOREprivodicircuitodilampeggio DIP 10 1_ SolopermotoriOLEODINAMICI Se nelle ultime 5 ore il cancello non ha effettuato manovre viene dato un impulso in chiusuradi2sec LOSTOPDISABILITALAFUNZIONE ON MANTENIMENTO BLOCCO OLEODINAMICO OFF MANTENIMENTOOLEODINAMICOdisattivato DIP2_1 L ingresso STOP 23 funziona come COSTA 8K2 e quando intercettato invertirà l...

Страница 8: ...nsoorariosiottengono103sec Ÿ RegolareiltrimmerP S TIMEimpostandoquindiiltempodisfasamentodesiderato Ÿ RegolareiltrimmerPAUSEimpostandoquindiiltempodipausadesiderato almaxinsensoorariosiottengono103sec Ÿ Impostareidipswitchperilfunzionamentodesiderato Ÿ Alimentareildispositivo Ÿ VerificarecheiledrossideicontattiN C sianoaccesieiledverdideicontattiN A sianospenti Ÿ Verificarechefacendointervenireifi...

Страница 9: ...F4 PLUS I 9 DESRCIZIONE MENU A 12 RIEPILOGO SEGNALAZIONI DA LAMPEGGIATORE Dispositivo Ssegnalazione Effetto Costa intercettata prima del moto 3 lampeggi lenti Porta bloccata NOTE ...

Страница 10: ...che i prodotti APPARECCHIATURA ELETTRONICA F4PLUS Sono conformi alle seguenti Direttive CEE e che sono state applicate le seguenti norme armonizzate Data 06 06 14 S r l DirettivaLVD2006 95 CE esuccessivemodifiche DirettivaEMC2004 108 CEesuccessivemodifiche EN60335 1 EN61000 6 2 EN61000 6 3 Il Rappresentante Legale Michele Prandi I ...

Страница 11: ...FICATIONS F4 PLUS 230 VAC single phase 50 60 Hz 1or 2 230VAC 230VAC 40W max 24VAC 3W max Plug in 20 C 60 C 24VAC 8W max Electronic control unit for automation of a swing gate sliding gate overheaddoororbarrierwithoneortwo230VACmotor Control unit Power supply No of motors Motor power supply Flashlight Warning light Radio receiver Operating temperature Accessory power supply Type WARNINGS This produ...

Страница 12: ...mproper use of the product may compromise system safety Keep all the materials contained in the packaging away from children since they pose a potential hazard The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitable for the specific application are not used When installation is complete always carefully check...

Страница 13: ...MOTOR 1 N C M3 COM FCCM2 FCAM2 FCCM1 Opening limit switch input MOTOR 1 N C 17 PHOTOCELL input N C 18 19 20 START input N O 24VAC output for PHOTOCELL ACCESSORIES power supply max 8W FCAM1 PHOTO START 24VAC 0VAC output for PHOTOCELL ACCESSORIES and ELECTRIC LOCK power supply 21 12VAC output for ELECTRIC LOCK max 15W 22 23 24 STOP input N C if DIP 11 IN OFF 8K2 FRAME input if DIP 11 IN ON PEDESTRIA...

Страница 14: ...MIT SWITCH of motor 1 is reached FCCM1 Always on Goes off when the OPENING LIMIT SWITCH of motor 1 is reached FCAM1 Always on Goes off when the photocell is intercepted interrupting the beam PHOTO Comes on when the START command is activated and goes off when released START Always on Goes off when the STOP button is activated open see DIP2_1 STOP Comes on when the PEDESTRIAN start command is activ...

Страница 15: ...MATIC logic Operation in response to the START command ŸGate closed OPENS ŸDuring opening UNINFLUENTIAL ŸGate open Reloads the automatic closing time if automatic closing is enabled otherwise it closes ŸDuring closing OPENS DIP 2 1_ STEP BY STEP WITH STOP logic Operation in response to the START command ŸGateclosed OPENS ŸDuringopening STOPS ŸGateopen PAUSE ŸDuringclosing OPENS Ÿ AfteraSTOP invert...

Страница 16: ...de the terminals 28 29 can be used to connect a FLASHLIGHT without a flashing circuit DIP 10 1_ ForHYDRAULICmotorsonly If the gate has not performed any operation in the last 5 hours a 2 second closing pulseisgiven ON HYDRAULIC LOCK RETENTION OFF HYDRAULICRETENTIONdeactivated DIP2_1 The STOP input 23 functions as 8K2 FRAME and when intercepted will invert the motion for 2 seconds in order to free ...

Страница 17: ...ng Ÿ AdjusttheRUNTIMEtrimmersettingthedesiredruntime uptomaximum103secondsturningclockwise Ÿ AdjusttheP S TIMEtrimmersettingthedesiredphaseshifttime Ÿ AdjustthePAUSEtrimmersettingthedesiredpausetime uptomaximum103secondsturningclockwise Ÿ SettheDIPswitchesforthedesiredoperation Ÿ Powerthedevice Ÿ CheckthattheredLEDsoftheN C contactsareonandthegreenLEDsoftheN O contactsareoff Ÿ Checkbytrippingtheli...

Страница 18: ...F4 PLUS 18 UK DESRCIZIONE MENU A 12 SUMMARY OF FLASHLIGHT SIGNALLING Device Signalling Effect Frame intercepted before motion 3 slow flashes Gate door locked NOTES ...

Страница 19: ... the product F4PLUS ELECTRONIC CONTROL UNIT is in conformity with the following EEC Directives and that the following harmonised standards have been applied Date 06 06 14 S r l LVDDirective2006 95 ECandsubsequentamendments EMCDirective2004 108 ECandsubsequentamendments EN60335 1 EN61000 6 2 EN61000 6 3 Legal Representative Michele Prandi ...

Страница 20: ...I DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC8787 05 2016 Rev 02 ...

Отзывы: