F4 PLUS
UK
15
Description
DIP
Status
Function
8 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP1_1
When the photocell is intercepted during both opening and closing, the gate motion
is locked until the photocell is freed. Subsequently, there is always an opening
phase. During pause, the photocell reloads the pause time.
ON
PHOTOCELL
DURING
OPENING
OFF
The photocell stops and immediately inverts the gate motion during closing while it
is uninfluential during opening. During pause, the photocell reloads the pause time.
ON
OPERATING
LOGIC
AUTOMATIC logic
Operation in response to the START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
UNINFLUENTIAL
→
Ÿ
Gate open
Reloads the automatic closing time if automatic
→
closing is enabled, otherwise it closes.
Ÿ
During closing
OPENS
→
DIP 2
1_
STEP-BY-STEP WITH STOP logic Operation in response to the START
command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
STOPS
→
Ÿ
Gate open (PAUSE)
→
Ÿ
During closing
OPENS
→
Ÿ
After a STOP
inverts the motion
→
STOPS
OFF
DIP 3
1_
Operation: following a START, OPENING or PEDESTRIAN command, the
following will occur in sequence:
Ÿ
electric lock activation
Ÿ
closing pulse of 1 second
Ÿ
opening
Ÿ
after 2 seconds, electric lock deactivation
This function cannot be activated with a sliding gate configuration and is
unadvisable with electromechanical operators.
ON
HAMMER STROKE
OFF
Hammer stroke disabled.
Simultaneous electric lock activation and opening.