CAUTION: It is important that an omnipolar magnetothermal switch with a minimum contact
opening of 3 mm be fitted upstream of the control unit.
Electric system setup
Set up the electric system as shown
(1a - 1b)
referring to the electric system regulations and other national
regulations in force. Keep the mains power connections clearly separated from the service connections (photocells,
sensitive frames, control devices, etc.).
The main components are:
1- Antenna; screened coaxial cable
2- Electronic control unit container
3- Electric lock; 1 mm² 2-core (2x1) cable
4- Key selector; 0,5 mm² 3-core (3x0,5) cable
5- 24Vdc operators:
- 1,5 mm² 2-core (2x1,5) cable power supply RED = + BLACK = -
for a cable length of 6 m max., over it’s necessary increase the cable section.
Cable with WHITE sheath for OPENING limit switch
Cable with BLACK sheath for CLOSING limit switch
6- Omnipolar magnetothermal switch with minimum contact opening of 3 mm
220-230V/50-60Hz control unit power line: min. 1,5 mm² 3-core cable (3x1,5)
(adhere to the regulations in force)
7- 24V flashing light; 0,75 mm² 2-core (2x0,75) cable
8- Connector blocks
9- Photocell transmitter; 0,5 mm² 2-core (2x0,5) cable
10- Photocell receiver; 0,5 mm² 4-core (4x0,5) cable
ELECTRICAL EQUIPMENT
UK
16
BL240
Содержание BL240
Страница 3: ...9 3 BL240 3 2 E 60 Cu C A d1 D 90 B 60 d1 per 90 a1 60 B 140 per 110 85 78 897 mm 109 mm 740 mm 151 mm...
Страница 4: ...BL240 4 8 9 6 7 100 120 B A 100 120 150 150 B A 4 5 E 60...
Страница 5: ...A B A B 10 11 BL240 5 15a 15b 14 13 12...
Страница 6: ...19b 19a BL240 6 15c 16 17 18 a b c...
Страница 7: ...BL240 7 20 21 3 4 5 6 4 3 6 5 3 4 7 2 1 5 1 2 7...