42
43
SC380
SC380
UK
UK
DESRCIZIONE MENU ( A )
18.3 - DESCRIPTION MENU ( H )
Menu
Function
Description
Status
Door opening time.
0 - 300 seconds (adjustable at intervals of 1 second )
25
MOTOR OPENING TIME
H 1
Door closing time.
0 - 300 seconds (adjustable at intervals of 1 second)
25
MOTOR CLOSING TIME
H 2
It determines the pause time in opening before the automatic
closing.
0 - 300 seconds (adjustable at intervals of 1 second)
20
AUTOMATIC CLOSING
PAUSE TIME
H 9
It determines the pedestrian opening time.
0 - 300 seconds ( adjustable at intervals of 1 second)
5
PEDESTRIAN OPENING
TIME
H 10
It determines the pause time in pedestrian opening before the
automatic closing.
0 - 300 seconds (adjustable at intervals of 1 second)
20
PEDESTRIAN AUTOMATIC
CLOSING PAUSE TIME
H 11
It determines the pause time before the automation
restarts the motion that had been interrupted after an
intervention of the EDGE and/or the MOTOR
REVOLUTIONS SENSOR (see menu E30).
0 - 60 seconds (adjustable at intervals of 1 second)
10
WAITING TIME FOR
REPEATED ATTEMPTS
AFTER SAFETY
DEVICES
INTERVENTION
H 19
DESRCIZIONE MENU ( A )
DESRCIZIONE MENU ( A )
18.4 - DESCRIPTION MENU ( E )
18.4 - DESCRIPTION MENU ( E )
Menu
Function
Description
Status
it disables the photocell test
1
It enables the test of all the safety inputs set as photocell 1 and
photocell 2.
Operation:
When the movement command of the gate (START,
OPENING, CLOSING, ETC) is given, the power supply to
transmitters is taken off for 1 second and then restored to check
its correct operation.
If the test fails, an anomaly is signalled by some blinkings of the
flashing light, see chapter 23.
With this function active, there will be a certain delay between
the opening/closing command and the enabling of the motor.
2
SAFETY INPUTS TEST SET
AS PHOTOCELL1 or
PHOTOCELL2
E 1
It disables the safety devices test.
1
This function enables the safety devices test SET AS EDGE
8K2 or EDGE NC.
Operation for EDGE 8K2:
All the safety inputs set as edge 8K2, after a command motion
star,t will be tested (8K2 value). If the value will not be
corrected, the anomaly will be signalled by some blinkings of
the flashing light, see chapter 23.
Operation for EDGE NC:
To check these devices it is necessary a suitable electronic
card.
When the command of gate movement (START, OPENING,
CLOSING, ETC) is given, the power supply to the control unit
is taken off for 1 second and then restored to check its correct
operation.If the test fails, an anomaly is signalled by some
blinkings of the flashing light, see chapter 23.
2
SAFETY DEVICES TEST
SET AS EDGE
E 3
ENERGY SAVING EXCLUDED.
1
ENERGY SAVING ENABLED.
Operation:
+24Vdc on terminal 32 will be present only during the operation
cycle.
Connecting the external accessories to this terminal, you can
have a significant energy saving during the rest phase of the
gate.
With this function enabled, there will be a certain delay between
the opening/closing command and the activation of the motor.
2
ENERGY SAVING
E 4
Operation :
During pedestrian closing, a PHOTO1 or PHOTO2 or
PEDESTRIAN or START command will cause the complete
opening
1
Operation:
During the pedestrian closing, a PHOTO1 or PHOTO2 or
PEDESTRIAN command will make open again only the
pedestrian.
START will cause the complete opening
2
INVERSION FROM
PEDESTRIAN
E 5
Menu
Function
Description
Status
Содержание AS05800
Страница 1: ...SC380 UK SC380 AS05800 AS05810 Electronic control unit INSTRUCTIONS FOR INSTALLATION ...
Страница 3: ...SC380 3 UK AS05800 31 6 236 1 2 8 236 31 6 AS05810 1 2 8 DIMENSIONS 1 ...
Страница 4: ...4 SC380 UK INSTALLATION 2 170 250 ...
Страница 54: ...54 SC380 UK NOTES ...
Страница 55: ...55 SC380 UK NOTES ...