
38
39
SC380
SC380
UK
UK
DESRCIZIONE MENU ( A )
DESRCIZIONE MENU ( A )
18.2 - DESCRIPTION MENU ( C )
18.2 - DESCRIPTION MENU ( C )
Menu
Function
Description
Status
Input DISABLED.
1
Input programmed as STOP
Operation:
STOP enabling blocks the automation and the restart of the
motion will occur only after a START / PEDESTRIAN / OPEN
/ CLOSE command.
2
programming of
SAFETY DEVICES No.2
input (terminal 25)
named PHOTO2
C 41
3
4
5
6
Input programmed as PHOTOCELL 1
Operation:
Input active only during the closing phase.
It stops the motion and inverts opening completely.
If intercepted in pause, it reloads the pause time.
If enabled, it allows the fast closing (see menu C1)
Input programmed as PHOTOCELL 2
Operation:
Input active both in opening and closing.
If intercepted, it stops the motion and keeps it blocked till when
it is not freed.
At release the motion restarts always in opening.
If intercepted in pause, it reloads the pause time.
Input programmed as EDGE 8K2.
Operation:
obstacle freeing way.
OPEN/ CLOSE, the motion restarts in opening or closing.
Input active both in opening and closing.
It stops the motion and inverts the movement for 2 seconds.
The gate will keep blocked waiting for a command:
START/PEDESTRIAN, the motion restarts towards the
Input programmed as EDGE N.C.
Operation:
See description of EDGE 8K2 operation
Menu
Function
Description
Status
Input DISABLED.
1
Input programmed as STOP
Operation:
STOP enabling blocks the automation and the restart of the
motion will occur only after a START / PEDESTRIAN / OPEN /
CLOSE command.
2
programming of the
SAFETY DEVICE No.3
input (terminal 26)
named SAFETY 1
C 42
3
4
5
5
6
Input programmed as PHOTOCELL 1
Operation:
Input active only during the closing phase.
It stops the motion and inverts opening completely.
If intercepted in pause, it reloads the pause time.
If enabled, it allows the fast closing (see menu C1)
Input programmed as PHOTOCELL 2
Operation:
Input active both in opening and closing.
If intercepted, it stops the motion and keeps it blocked till when
it is not freed.
At release the motion restarts always in opening.
If intercepted in pause, it reloads the pause time.
Input programmed as EDGE 8K2.
Operation:
obstacle freeing way.
OPEN/ CLOSE, the motion restarts in opening or closing.
Input active both in opening and closing.
It stops the motion and inverts the movement for 2 seconds.
The gate will keep blocked waiting for a command:
START/PEDESTRIAN, the motion restarts towards the
Input programmed as EDGE N.C.
Operation:
See description of EDGE 8K2 operation
Содержание AS05800
Страница 1: ...SC380 UK SC380 AS05800 AS05810 Electronic control unit INSTRUCTIONS FOR INSTALLATION ...
Страница 3: ...SC380 3 UK AS05800 31 6 236 1 2 8 236 31 6 AS05810 1 2 8 DIMENSIONS 1 ...
Страница 4: ...4 SC380 UK INSTALLATION 2 170 250 ...
Страница 54: ...54 SC380 UK NOTES ...
Страница 55: ...55 SC380 UK NOTES ...