background image

3

PULLEY INFORMATION

Pulley selection and pump speed are based on a 1725 
RPM motor and “B” section belts.  When selecting de-
sired GPM, allow for a ±5% tolerance on pumps output 
due to variations in pulleys, belts and motors among 
manufacturers.
1.      Select GPM required, then select appropriate 
motor and pump pulley from the same line.
2.   The desired pressure is achieved by selecting the cor-
rect nozzle size that corresponds with the pump GPM. 

HORSEPOWER INFORMATION

We recommend that a 1.15 service factor be 

specified when selecting an electric motor as the 

power source.  To compute specific pump horse

-

power requirements, use the following formula:

  HP = (GPM X PSI) / 1440

 

U.S. 

Metric

Volume....................................................................9.8 GPM ...................................................................

37 LPM

Discharge Pressure ................................................5800 PSI ...................................................................400 Bar
Inlet Pressure .........................................................140 PSI ......................................................................9.7 Bar
Speed .................................................................................................................................................. 1000 RPM
Plunger Diameter....................................................0.79” .......................................................................... 20 mm 
Stroke .....................................................................1.65” .......................................................................... 42 mm
Crankcase Oil Capacity ..........................................

100 fl.oz.

 .....................................................................

3 liters

Temperature of Pumped Fluids ..............................140

F ...........................................................................60 

o

C

Inlet Port ......................................................................................................................................

3 x 1-1/4” FNPT

Discharge Port ...................................................................................................................................

3 x 1” FNPT

Crankshaft Mounting ...........................................................................................................................Either Side
Shaft Rotation .................................................................................................... Top of Pulley Towards Fluid End
Weight ....................................................................

132 lbs.

 .........................................................................60 kg 

Crankshaft Diameter..................................................................................................................................

35 mm

LP600-5100 Specifications

LP301A-5100 PULLEY SELECTION AND 

HORSEPOWER REQUIREMENTS

RPM GPM 2500 PSI

3000 PSI 3500 PSI

4000 PSI

500

7.1

12.2

14.7

17.1

19.6

640

9.0

15.6

18.8

21.9

25.1

750

10.6

18.4

22.0

25.7

29.4

805

11.4

19.7

23.6

27.6

31.5

865

12.2

21.2

25.4

29.6

33.9

940

13.3

23.0

27.6

32.2

36.8

1000 14.1

24.5

29.4

34.3

39.2

LP600-5100 PULLEY SELECTION AND 

HORSEPOWER REQUIREMENTS

RPM GPM

3000 PSI

4000 PSI 5000 PSI 5800 PSI

500

4.9

10.2

13.6

17.0

19.7

640

6.2

12.9

17.2

21.5

25.0

750

7.3

15.2

20.3

25.3

29.4

805

7.8

16.3

21.7

27.1

31.4

865

8.4

17.5

23.3

29.2

33.8

940

9.1

19.0

25.3

31.6

36.7

1000

9.8

20.4

27.2

34.0

39.5

 

U.S. 

Metric

Volume....................................................................14.2 GPM ..............................................................

53.6 LPM

Discharge Pressure ................................................

3900 PSI

 ...................................................................270 Bar

Inlet Pressure .........................................................140 PSI ......................................................................9.7 Bar
Speed .................................................................................................................................................. 1000 RPM
Plunger Diameter....................................................0.94” .......................................................................... 24 mm 
Stroke .....................................................................1.65” .......................................................................... 42 mm
Crankcase Oil Capacity ..........................................

100 fl.oz.

 .....................................................................

3 liters

Temperature of Pumped Fluids ..............................140

F ...........................................................................60 

o

C

Inlet Port ......................................................................................................................................

3 x 1-1/4” FNPT

Discharge Port ...................................................................................................................................

3 x 1” FNPT

Crankshaft Mounting ...........................................................................................................................Either Side
Shaft Rotation .................................................................................................... Top of Pulley Towards Fluid End
Weight ....................................................................

132 lbs.

 .........................................................................60 kg 

Crankshaft Diameter..................................................................................................................................

35 mm

LP301A-5100 Specifications

Содержание LP301A-5100

Страница 1: ...Instructions page 7 10 Pump Mounting Selection Guide page 10 Torque Specifications page 10 Troubleshooting Preventative Maintenance Check List Recommended Spare Parts List page 11 Dimensions back page...

Страница 2: ...ump dry approximately 10 seconds to drain the water before exposure to freezing temperatures 1 Prior to initial operation add oil to the crankcase so that oil level is between the two lines on the oil...

Страница 3: ...Side Shaft Rotation Top of Pulley Towards Fluid End Weight 132 lbs 60 kg Crankshaft Diameter 35 mm LP600 5100 Specifications LP301A 5100 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS RPM GPM 2500 PSI...

Страница 4: ...ainless steel valve plugs 48 can seize when being screwed out of the casing To release tension beforehand strike the plugs 1 2 times with a steel hammer on the top before screw ing them out Coat threa...

Страница 5: ...301A 5100 3 37 13239 0100 Seal Case LP600 5100 3 37 13240 0100 Seal Case LP301A 5100 3 38 07140 O Ring Seal Case 3 38A 13241 Support Ring for 38 3 LP301A 5100 LP600 5100 Parts List BSP to NPT Adapters...

Страница 6: ...00 Pressure Ring 3 40C 05963 Sleeve 3 Valve Kits LP301A 5100 09196 0100 Item Part Description Qty 44A 07150 O Ring 9 44B 06266 Support Ring 3 46A 07064 0100 Valve Seat 6 46B 07063 0100 Valve Plate 6 4...

Страница 7: ...A and tension spring 45 3 Take out discharge valve assemblies 46 by pulling them upwards out of the valve casing 43 with a snap ring tongs or any other pull off device Then remove inlet valves in the...

Страница 8: ...and support rings 39A 38A on seal case 37 39 39A 37 38A 38 10 Remove leakage seal 36 from the seal sleeve If worn or dam aged replace with new seal 11 Remove the guide ring 40A v sleeves 40 40C and su...

Страница 9: ...r ceramic plunger side and tighten screw to 265 in lbs 30 NM 29B 29D 29C 13 Replace complete seal sleeve 35 seal case 37 assembly into crankcase 1 Make sure that the weep hole points down ward Note To...

Страница 10: ...ines up with the outer edge of the bearing hole Remove bearing cover 14 together with radial shaft seal 15 and o ring 16 Fit crank shaft 22 through bearing hole on the opposite side Press in outer bea...

Страница 11: ...n inlet of pump for restrictions Unloader Check for proper operation Water in crankcase High humidity Reduce oil change interval Worn seals Replace seals Noisy Operation Worn bearings Replace bearings...

Страница 12: ...ar parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the customer or third party 6 T...

Отзывы: