Specifications
Model HR3025
Axial Pump
Volume HR3030....................................................................................3.0 GPM
Maximum Discharge Pressure .............................................................2500 PSI
Maximum Inlet Pressure ......................................................................Up to 90 PSIG
1
RPM .....................................................................................................3450
Plunger Diameter ..................................................................................16mm
Stroke ....................................................................................................5.9mm (8.0
o
angle)
Crankcase Oil Capacity ........................................................................4.5 fl. oz.
Temperature of Pumped Fluids .............................................................Up to 80
o
F
Inlet Port ...............................................................................................1 x 1/2" NPT
Discharge Ports ....................................................................................3/8" NPT
Shaft Rotation .......................................................................................Clockwise
Weight ...................................................................................................11.4 lbs.
Width .....................................................................................................6-7/16"
Height ...................................................................................................10-1/4"
Swash Plate Bore .................................................................................3/4 x 3/16 Keyway
Valve Type ............................................................................................Polyamide Plastic
1
A 25 PSIG minimum inlet pressure is required.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the pump. Gas
engine power outputs must be
approximately twice the pump power
requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse-
power requirements, use the Follow-
ing formula:
Electric HP = (GPM X PSI) / 1460
Gas HP = (GPM X PSI) / 1100
HR3025 ELECTRIC HORSEPOWER
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI
3450
3.0
2.1
3.1
4.1
5.1
HR3025 GAS HORSEPOWER
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI
3450
3.0
2.7
4.1
5.5
6.8
4
Содержание HR2527A