background image

3

Consult the factory for special requirements that 

must be met if the pump is to operate beyond 

one or more of the limits specified above. 

Horsepower Ratings:

  We recommend a 1.15 service factor be specified when selecting an electric motor as the power source.  

  To compute electric motor

 horsepower required, use the following formula:    HP = (GPM X PSI) / 1450.

  The formula to determine the horsepower required for a gas engine is:  HP = (GPM X PSI) / 1150.

  The formula to determine the horsepower required for a diesel engine is:  HP = (GPM X PSI) / 1250.

  

 

For the Application of a Hydraulic Motor:

 

To Determine the Torque of a Hydraulic Motor  --  (GPM x PSI x 36.77) / RPM = Torque (in-lbs)

 

   

Calculating RPM / GPM of Pump:

 

     

A pump must be connected to an electric motor or gas or diesel engine with the correct ratio of pulleys 

   and belts to attain the required speed and GPM. The use of a Variable Frequency Drive (VFD) may also 

   be used to control the RPM of a properly sized electric mot

or when variable flows are required. 

       (Max. Pum

p RPM / Rated Pump GPM) x Required Pump GPM = 

Required Pump RPM

  To calc

ulate a pulley diameter one (1) pulley diameter and the required pump RPM must be known:

    

(Pump RPM x Pump Pulley Diameter) / Motor RPM = Motor Pulley Diameter

             

(Motor RPM x Motor Pulley Diameter) / Pump RPM = Pump Pulley Diameter

Common Specifications:

Inlet Pressure ..

-4.35 to 145 PSI (-0.3 to 10 Bar)

Max. Temperature ..................140 

o

F (60 

o

C)

Crankshaft Diameter..............

1.38” (35mm)

Crankcase Oil Capacity .........

1.2 Gal. (4.6 L)

Inlet Ports ..............................

(2) 3/4” BSP

Discharge Ports .....................

(2) 1/2” BSP

Stroke ....................................

1.81” (46mm)

Weight ...................................

176 lbs (80 kg)

Shaft Rotation ..Top of Pulley Toward Fluid End 

 Materials Used for MP Pumps:

 Manifold ........

AISI 303 Stainless Steel

 Plungers ....... Solid Ceramic

 Valves ........... Duplex Steel

 Seals.............

Aramide/Teflon Packing

 Gear End ...... Spheroidal Cast Iron

 Crankshaft .... Drop-forged and case-hardened

GP5120/GP5122/GP5124 SERIES PUMP SPECIFICATIONS

Max. 

Flow

Max. 

Pressure

Max. 

Speed

Power 

Req’d.

Max. 

Temp.

Plunger 

Diameter

NPSH 

Required

Model

GPM

PSI

RPM

HP

°F

in

Ft-Head

GP5120

10.5

8700

1000

63.3

140

0.787

27.9

GP5122

11.9

7250

930

59.0

140

0.866

27.9

GP5124

13.2

5800

850

53.8

140

0.945

27.9

Max. 

Flow

Max. 

Pressure

Max. 

Speed

Power 

Req’d.

Max. 

Temp.

Plunger 

Diameter

NPSH 

Required

Model

L/min

Bar

RPM

kW

°C

mm

mWs

GP5120

40.0

600

1000

47.2

60

20

8.5

GP5122

45.0

500

930

44.0

60

22

8.5

GP5124

50.0

400

850

40.1

60

24

8.5

Содержание GP5122

Страница 1: ...tions page 3 Exploded View page 4 Parts List page 5 Kits Torque Specs page 6 Repair Instructions page 7 Dimensions back page Warranty Information back page Models GP5120 GP5122 GP5124 Triplex Ceramic...

Страница 2: ...id spraying units so that the admissible operating pressure cannot be exceeded by more than 10 Pump operation without a safety valve as well as any excess in temperature or speed limits automatically...

Страница 3: ...M To calculate a pulley diameter one 1 pulley diameter and the required pump RPM must be known Pump RPM x Pump Pulley Diameter Motor RPM Motor Pulley Diameter Motor RPM x Motor Pulley Diameter Pump RP...

Страница 4: ...4 EXPLODED VIEW GP5120 GP5122 GP5124 PUMPS...

Страница 5: ...GP5124 3 33A 04491 Centring Ring GP5120 3 33A 04502 Centring Ring GP5122 3 33A 04508 Centring Ring GP5124 3 34 06589 Plug 1 8 BSP 6 35 06709 Seal 6 GP5120 GP5122 GP5124 SPARE PARTS LIST ITEM PART DESC...

Страница 6: ...8 07303 O Ring 3 39 04381 Guide Ring 3 40 07718 Support Ring 3 41 07685 Spiral Ring 6 44 12055 O Ring 3 45 07693 Support Ring 3 47 06266 Support Ring 3 48 07150 O Ring 3 Valve Assembly and Oil Seal Ki...

Страница 7: ...the front surface can cause the plunger pipe to fracture The seal sleeves must be fitted so that grooved pins 37 are on top Put tension spring 43 into seal casing 33 and place the seal case 46 into th...

Страница 8: ...ar to standard wear parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the customer o...