3
Consult the factory for special requirements that
must be met if the pump is to operate beyond
one or more of the limits specified above.
Horsepower Ratings:
We recommend a 1.15 service factor be specified when selecting an electric motor as the power source.
To compute electric motor
horsepower required, use the following formula: HP = (GPM X PSI) / 1450.
The formula to determine the horsepower required for a gas engine is: HP = (GPM X PSI) / 1150.
The formula to determine the horsepower required for a diesel engine is: HP = (GPM X PSI) / 1250.
For the Application of a Hydraulic Motor:
To Determine the Torque of a Hydraulic Motor -- (GPM x PSI x 36.77) / RPM = Torque (in-lbs)
Calculating RPM / GPM of Pump:
A pump must be connected to an electric motor or gas or diesel engine with the correct ratio of pulleys
and belts to attain the required speed and GPM. The use of a Variable Frequency Drive (VFD) may also
be used to control the RPM of a properly sized electric mot
or when variable flows are required.
(Max. Pum
p RPM / Rated Pump GPM) x Required Pump GPM =
Required Pump RPM
To calc
ulate a pulley diameter one (1) pulley diameter and the required pump RPM must be known:
(Pump RPM x Pump Pulley Diameter) / Motor RPM = Motor Pulley Diameter
(Motor RPM x Motor Pulley Diameter) / Pump RPM = Pump Pulley Diameter
Common Specifications:
Inlet Pressure ..
-4.35 to 145 PSI (-0.3 to 10 Bar)
Max. Temperature ..................140
o
F (60
o
C)
Crankshaft Diameter..............
1.38” (35mm)
Crankcase Oil Capacity .........
1.2 Gal. (4.6 L)
Inlet Ports ..............................
(2) 3/4” BSP
Discharge Ports .....................
(2) 1/2” BSP
Stroke ....................................
1.81” (46mm)
Weight ...................................
176 lbs (80 kg)
Shaft Rotation ..Top of Pulley Toward Fluid End
Materials Used for MP Pumps:
Manifold ........
AISI 303 Stainless Steel
Plungers ....... Solid Ceramic
Valves ........... Duplex Steel
Seals.............
Aramide/Teflon Packing
Gear End ...... Spheroidal Cast Iron
Crankshaft .... Drop-forged and case-hardened
GP5120/GP5122/GP5124 SERIES PUMP SPECIFICATIONS
Max.
Flow
Max.
Pressure
Max.
Speed
Power
Req’d.
Max.
Temp.
Plunger
Diameter
NPSH
Required
Model
GPM
PSI
RPM
HP
°F
in
Ft-Head
GP5120
10.5
8700
1000
63.3
140
0.787
27.9
GP5122
11.9
7250
930
59.0
140
0.866
27.9
GP5124
13.2
5800
850
53.8
140
0.945
27.9
Max.
Flow
Max.
Pressure
Max.
Speed
Power
Req’d.
Max.
Temp.
Plunger
Diameter
NPSH
Required
Model
L/min
Bar
RPM
kW
°C
mm
mWs
GP5120
40.0
600
1000
47.2
60
20
8.5
GP5122
45.0
500
930
44.0
60
22
8.5
GP5124
50.0
400
850
40.1
60
24
8.5
Содержание GP5122
Страница 4: ...4 EXPLODED VIEW GP5120 GP5122 GP5124 PUMPS...