background image

E/PUMP WITH ELECTRONIC FLOW CONTROL 
CONTROL PRESS 

 
 
                          
 

ECOINOX C.E.

 

 

 

ECOJET C.E. 

 

JET C.E. 

 
 

      
    
              I

           Manuale uso e manutenzione 

 

 

 

              

UK           

Operating and maintenance manual

 

 
 
 
 
 
 

 
 
 
 

 
 
 
 

Ed. 02/2011 
 
 
 

Содержание ECOINOX C.E.

Страница 1: ...E PUMP WITH ELECTRONIC FLOW CONTROL CONTROL PRESS ECOINOX C E ECOJET C E JET C E I Manuale uso e manutenzione UK Operating and maintenance manual Ed 02 2011...

Страница 2: ...lare i modelli ECOJET B bronzo ECOINOX inox ECOJET G ghisa JET G ghisa sono specifiche per acqua dolce mentre i modelli ECOJET BB bronzo bronzo JET B bronzo sono idonee sia per acqua dolce che di mare...

Страница 3: ...ollevato e maneggiato con cura ISPEZIONI PRELIMINARI Estrarre il prodotto dall imballo assicurando la presa nella sola parte relativa all EL POMPA e verificarne l integrit verificare inoltre che i dat...

Страница 4: ...del tubo dalla lunghezza orizzontale del tubo d aspirazione ed dal livello d acqua La portata massima dipende dal diametro del tubo altezza aspirazione altezza mandata perdite di carico delle condutt...

Страница 5: ...tropompa e pu recare danno all am biente circostante Per ridurre ulteriormente l eventuale trasmissione di vibrazioni lungo la tubazione inserire tra queste e le pompa dei giunti antivibranti Controll...

Страница 6: ...trol Press 1Ph e El Pompa 3Ph ma non si fornisce il teleruttore In opzione forniamo quadretto di collegamento per una o pi unit Le pompe devono essere collegate solo da personale qualificato in confor...

Страница 7: ...rente in uscita non superiore a MAX 22 A Connection by means of a remote control switch for 24V D C motors with an output current not exceeding MAX 22 A Collegamento diretto del motore 230V monofase c...

Страница 8: ...corpo pompa con acqua 5 Stringere il tappo di innesco 6 Aprire la valvola sulla linea di aspirazione 7 Chiudere la valvola sulla linea di mandata 8 Accendere la pompa ed aprire lentamente la valvola...

Страница 9: ...caso tenere premuto il pulsante rosso Restart riarmo ed attendere con un utilizzo aperto che si spenga la spia rossa Chiuso l utilizzo l apparecchio ferma la pompa e si pone in posizione di attesa sp...

Страница 10: ...e qualificato dopo aver staccato l alimentazione Nessuna manutenzione programmata richiesta a condizione che siano osservate le seguenti precauzioni Se c rischio di congelamento necessario svuotare il...

Страница 11: ...UREZZA Prima dell installazione assicurarsi che la rete di alimentazione sia conforme alle norme vigenti sia dotata di messa a terra e risponda a i dati di targa del motore Prima di qualsiasi interven...

Страница 12: ...OJET B bronze ECOINOX inox ECOJET G and JET G cast iron have to work with fresh water and the models ECOJET BB bronze bronze JET B bronze are fitted either for fresh or sea water The use of these mach...

Страница 13: ...th care When lifting and moving pump ensure it is firmly held and supported PRELIMINARY INSPECTIONS Unpack the pump and check its integrity Furthermore check that the details on the plate corresponds...

Страница 14: ...capability depends on pipe diameter lengths of horizontal suction pipe and water level The maximum delivery depends on pipe diameter suction lift delivery head head losses in the suction delivery pip...

Страница 15: ...ions depends the delivery of the pump Pumps are supplied with thread ports so three pipe unions are recommended at suction and delivery ports Working with leakage from the pipes or from the shaft dama...

Страница 16: ...k ELECTRICAL CONNECTIONS These machines are delivered ready to be connected The pump should be connected by qualified personnel only in accordance with local directive or standard Make sure that there...

Страница 17: ...rente in uscita non superiore a MAX 22 A Connection by means of a remote control switch for 24V D C motors with an output current not exceeding MAX 22 A Collegamento diretto del motore 230V monofase c...

Страница 18: ...priming plug 6 Open the valve on the suction line 7 Close the valve on the outlet line 8 Turn the pump on and open slowly the valve on the outlet line 9 Check the running direction 10 After closing th...

Страница 19: ...p the red Restart button pressed in and wait with a tap opened for the red light to turn off Once the tap has been closed the device stops the pump and moves into standby with the green light turned o...

Страница 20: ...precautions are taken If there is a risk of freezing it is necessary to empty the pump casing then fill the pump before it gets working again and be sure the ambient temperature is over the water fre...

Страница 21: ...the water stops OK Pump is re pressuring system SAFETY Before installation ensure that mains supply is grounded in accordance with local legislation and corresponds to motor plate detail Before carryi...

Страница 22: ...differenza di altri prodotti che sono realizzati con materiali e componenti pi poveri spesso non ammessi dalle normative CEE MATERIAL DELCARATION C E Body non return valve rear part and safety valve a...

Страница 23: ...posizioni delle direttive vigenti e ai regolamenti di classe applicabili Dichiara inoltre che la marcatura apposta sulla targhetta del prodotto DECLATATION OF CONFORMITY Under Annex II of the Machiner...

Страница 24: ...posizioni delle direttive vigenti e ai regolamenti di classe applicabili Dichiara inoltre che la marcatura apposta sulla targhetta del prodotto DECLATATION OF CONFORMITY Under Annex II of the Machiner...

Отзывы: