Giandel PS-4000QAR Скачать руководство пользователя страница 7

10.

11.

13. WARRANTY

          We  take  the  guarantee  of  one  year  from  the  purchasing  day.  During  the  guarantee 

period,  any  malfunction  caused  by  our  product  quality,  our  company  will  fix  or  replace 

the unit for free. But any one of the following conditions is beyond our guarantee terms.

1. The  box  distorted,  damaged  or  changed,  and  interior  parts  damaged  because  of  the 

exterior hit or drop.

2. Connect the DC power adversely.

3. Dismantled or repaired the unit by un-granted person.

4. The unit was damaged by incorrect installation or operating method.

B. TROUBLESHOOTING TIPS

 Reduce the load power, or turn on the

 

appliance first, then turn on the inverter.

 Choose a bigger inverter

 Change a bigger battery and ensure fully

 

charged.

No output voltage,
buzzer whistles 
continuously

Problem 

Reason 

Solutions

Low Input DC Voltage

High Input DC Voltage

Overload

Over temperature

 Check the rated voltage of the battery and

 

make sure that it is in the allowable range of

 

the input voltage.

 Do not use it when the battery is charging

Reduce the load power

 Restart it after it resumes to normal 

temperature. Reduce the load. avoid 
blocking the vent and improve the 
ventilation condition.

 Cut off the load and let it cool naturally for 

10 to 30 minutes.

No AC output

 

voltage?

1.The power switch is off.
2.Poor contact with battery.

Check  the  cables  and  make  sure  they  are 
tightly connected.

 Press the power switch for 1-2 second to 

turn it on. it is a long press type switch

Output voltage

 

below 

100 V AC?

“True RMS”voltage meter is
required to properly measure 
output

 

voltage of modified 

wave inverter

Cannot drive the

 

load?

Tester indicated 
"Open Ground"?

This is because it is not connected 
to a"true Earth ground ", meaning it 
is not connected to a metal rod 
stuck in the

 

Earth. it would be 

impossible to do so in a boat or car 
while moving. The power

 

inverter 

DOES NOT and cannot create a 
true Earth ground on its own. 

 Change the battery of the meter then test

 

again. 

 Try to maintain the input voltage in the

 

range of rated power

 Test output voltage with a True RMS meter

3.Battery is too small.

2.The starting power is larger than 

rated

 

power (especially for 

appliances with

 

motor)

1.Load power is too large. Or the 

actual

 

power of the appliance 

exceeds

 

nominal power.

 Refer to the manual to do the Grounding

 Don't need the tester to do the Grounding

 

Test.

Starting alarm ?

instantaneous current is too large, 
which leads to the detection of low 
voltage and trigger under-voltage 
alarm.

The main reason is that ths

Please restart the inverter several 
times.

Got 40V or so while

 

testing inverter's

 

ground wire and
zero line?

This voltage has no meaning, 
zero

 

line can be ground. 

This is normal, there is no current 
leakage.

Low Input DC Voltage

If the unit still doesn't work normally after using all the methods above, it maybe 
the internal faults of the circuit. Please contact seller for warranty.