2.
Grounding
Thermal control cooling fan
DC input connector (+)
DC input connector (-)
4. ASSEMBLE
1. The position of Mounting
First ensure that there is enough space to install the inverter, while the installation
location must meet the following requirements:
(1) Dryness: Avoid dripping water or other liquids on the inverter.
(2) Coolness: The working temperature of environment for the product is 0-40
℃
, the
preferable temperature is 10-25
℃
, the lower the temperature is better within this range.
(3) Ventilation: There should be a certain distance between inverter and other objects, to
avoid blocking the product's vents.
(4) Cleanness: Do not install the product in the dusty, wood chips or other particles. Or
cooling fan is turned on, the particles will be involved in the inside of the product, thus
affecting the normal work.
(5) When connecting inverters and batteries, it will produce arcs or sparks, so there
should not be flammable objects around, such as gasoline, alcohol, etc.
2. Assemble the inverter
For this big power inverter, preferably mounted on a solid platform because of the
heavy weight, such as floor, table or stable support. In order to avoid sliding off, the
platform should bear the weight of the product, and it is better to fix the product with four
screws.
3.
478mm
128mm
(1)Rear panel:
Remote control interface
AC output socket
AC output terminal
Power ON/OFF switch
15) Avoid unintentional starting. Be sure the switch is in the OFF position when not in use
and before plugging in any appliance. Disconnect the battery and inverter when not in
use for a long time.
16) Keep inverter away from children. Don't install the inverter where it is accessible to
children.
17) The power inverter will output the same AC power as utility power, please treat the AC
outlets as carefully as you would your home AC outlets. Do not put anything other than
an electrical appliance into the output terminal. It may cause shock or fire.
18) This product cannot be used for medical and life support equipment.
Normal working indicator
Remote interface
Connecting wire
Fault indicator
Power switch
(Switch)